首页> 外文期刊>IEEE sensors journal >A Novel Lead-Wire-Resistance Compensation Technique Using Two-Wire Resistance Temperature Detector
【24h】

A Novel Lead-Wire-Resistance Compensation Technique Using Two-Wire Resistance Temperature Detector

机译:利用两线电阻温度检测器的新型引线电阻补偿技术

获取原文
获取原文并翻译 | 示例

摘要

A novel lead-wire-resistance compensation technique using two-wire resistance temperature detectors is presented here. This technique compensates the effect of both identical and nonidentical lead-wire resistances in the measurements. The measured error is comparable with both conventional three-wire and four-wire techniques and lies within plusmn0.15% of reading the resistance. The proposed technique also reduces self-heating by 50%. It is quite conveniently adaptable in industry
机译:本文介绍了一种使用两线电阻温度检测器的新型引线电阻补偿技术。该技术补偿了测量中相同和不同的引线电阻的影响。测得的误差可与常规三线和四线技术相媲美,并且在读取电阻值的0.15%以内。所提出的技术还将自身发热降低了50%。在行业中非常方便地适应

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号