首页> 外文期刊>Sensors and Actuators >Sensitivity of guided mode resonance filter-based biosensor in visible and near infrared ranges
【24h】

Sensitivity of guided mode resonance filter-based biosensor in visible and near infrared ranges

机译:基于导模共振滤波器的生物传感器在可见光和近红外范围内的灵敏度

获取原文
获取原文并翻译 | 示例
           

摘要

The sensitivity of guided mode resonance filter (GMRF) biosensors was analyzed when the initial peak wavelength (IPW) changed from 400 to 1600 nm. The sensitivity of the GMRF to the sample refractive index and thickness was analyzed using rigorous coupled wave analysis method. Results indicate that for a certain IPW, the sensitivity of the GMRF did not change when the sample refractive index varied, but drastically decreased and achieved constant sensitivity with increased sample thickness. When the IPW increased, the sensitivity improved in relation to both sample refractive index and sample thickness. Furthermore, the capability of sample thickness improved with longer IPW. These results are helpful in obtaining an optimal GMRF biosensor.
机译:当初始峰值波长(IPW)从400 nm更改为1600 nm时,分析了导模共振滤波器(GMRF)生物传感器的灵敏度。使用严格的耦合波分析方法分析了GMRF对样品折射率和厚度的敏感性。结果表明,对于一定的IPW,当样品的折射率发生变化时,GMRF的灵敏度没有改变,但随着样品厚度的增加,GMRF的灵敏度急剧下降并达到了恒定的灵敏度。当IPW增加时,灵敏度相对于样品的折射率和样品的厚度都有所提高。此外,更长的IPW可以提高样品厚度的能力。这些结果有助于获得最佳的GMRF生物传感器。

著录项

  • 来源
    《Sensors and Actuators》 |2011年第1期|p.194-197|共4页
  • 作者单位

    Shanghai Key Laboratory of Contemporary Optics System, College of Optics and Electronics, University of Shanghai for Science and Technology,516 Jungong Road,Shanghai 200093, China;

    Shanghai Key Laboratory of Contemporary Optics System, College of Optics and Electronics, University of Shanghai for Science and Technology,516 Jungong Road,Shanghai 200093, China;

    Shanghai Key Laboratory of Contemporary Optics System, College of Optics and Electronics, University of Shanghai for Science and Technology,516 Jungong Road,Shanghai 200093, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    biosensor; sensitivity; peak wavelength; guided mode resonance filter (cmrf);