A novel BOD biosensor was fabricated based on activated sludge (AS) entrapped in a chitosan-bovine serum albumin (Chi-BSA) cryogel. Methylene blue (MB) was used as the mediator and electron transfer was enhanced using graphene. The responses of glucose glutamic acid (GGA) solutions were amperometrically measured with an applied potential of -0.20 V versus Ag/AgCl in a flow injection system. Under the optimum conditions, the graphene/MB/Chi-BSA-AS cryogel demonstrated a high operational stability of up to 140 analyses (RSD = 2.9%), a good storage stability (65 days) and a wide linear range, from 1.0-100mg O_2 L~(-1). At a flow rate of 400 μL min~(-1) the detection limit (LOD) was 1.0 mg O_2 L~(-1) with a 9 min analysis time. A lower LOD (0.10 mg O_2 L~(-1)) could be measured at a lower flow rate of 100 μL min~(-1) and wastewater with a low BOD value could be measured. In comparison with the standard BOD_5 method, the BOD concentrations in the waste water samples measured by this method were in good agreement (P>0.05). These results demonstrated the potential of this graphene/MB/Chi-BSA-AS cryogel BOD biosensor. The use of this cryogel platform as a microbe immobilization support for other biosensor developments is promising.
机译:基于截留在壳聚糖-牛血清白蛋白(Chi-BSA)冷冻凝胶中的活性污泥(AS),制造了新型BOD生物传感器。亚甲基蓝(MB)被用作介体,并且使用石墨烯增强了电子转移。在流动注射系统中,相对于Ag / AgCl,在-0.20 V的施加电势下对葡萄糖谷氨酸(GGA)溶液的响应进行了安培测量。在最佳条件下,石墨烯/ MB / Chi-BSA-AS冷冻凝胶显示出高达140次分析的高操作稳定性(RSD = 2.9%),良好的储存稳定性(65天)和从1.0- 100mg O_2 L〜(-1)。在400μLmin〜(-1)的流速下,检测限(LOD)为1.0 mg O_2 L〜(-1),分析时间为9分钟。在100μLmin〜(-1)的较低流速下可以测出较低的LOD(0.10 mg O_2 L〜(-1)),并且可以测量出BOD值较低的废水。与标准BOD_5方法相比,该方法测得的废水样品中的BOD浓度吻合良好(P> 0.05)。这些结果证明了该石墨烯/ MB / Chi-BSA-AS冷冻凝胶BOD生物传感器的潜力。将此冷冻凝胶平台用作其他生物传感器开发的微生物固定化支持是有希望的。

著录项

  • 来源
    《Sensors and Actuators》 |2017年第3期|473-481|共9页
  • 作者单位

    Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand;

    Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Department of Applied Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand;

    Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand;

    Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Department of Biochemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand;

    Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Department of Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand;

    Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand,Department of Physics, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Cell-based biosensor; BOD; Entrapped activated sludge; Cryogel; Graphene; Methylene blue;

    机译:基于细胞的生物传感器;董事会截留的活性污泥;低温凝胶石墨烯亚甲蓝;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号