ENEA EXTREMITY DOSEMETER BASED ON LiF(Mg,Cu,P) TO EVALUATE H_p(3,α)

机译:基于LiF(Mg,Cu,P)的ENEA极端剂量计评估H_p(3,α)

获取原文
获取原文并翻译 | 示例
           

摘要

Recent epidemiological studies suggest a rather low-dose threshold (<0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimised and current dose limits for the eye lens may be reduced in the future. ICRP Publication 103 on H_p(d), in §(136), reads that'... a depth d=3 mm has been proposed for the rare case of monitoring the dose to the lens of the eye. In practice, however, H_p(3) has rarely been monitored and H_p(0.07) can be used for the same monitoring purpose...'. As recommended on the EU 'Technical recommendations for monitoring individuals occupationally exposed to external radiation', a test on the ENEA TL extremity dosemeter is herein reported. The results within the actual EU founded Optimization of RAdiation protection for MEDical staff (ORAMED) Project, whose WP2 is aimed at the quantity H_p(3) and eye lens dosimetry in practice, are taken into account. The paper summarises the main aspects of the study carried out at ENEA-Radiation Protection Institute (Bologna, Italy) to provide practical solutions (in the use and the design) to evaluate the response of the ENEA TL extremity dosemeter in terms of H_p(3).
机译:最近的流行病学研究表明,诱发晶状体白内障的剂量阈值较低(<0.5 Gy)。其他一些研究甚至假设根本没有阈值。因此,必须优化保护措施,并且将来可能会降低目镜的当前剂量限制。 §(136)中关于H_p(d)的ICRP出版物103读到...对于一种罕见的监视眼睛晶状体剂量的建议,建议深度d = 3 mm。但是实际上,很少监视H_p(3),并且H_p(0.07)可以用于相同的监视目的...'。根据欧盟“监测职业性暴露于外部辐射的个人的技术建议”的建议,在此报告了对ENEA TL极端剂量计的测试。考虑了实际在欧盟建立的医务人员最佳辐射防护(ORAMED)项目中的结果,该项目的WP2旨在针对H_p(3)量和实践中的晶状体剂量。本文总结了在ENEA-辐射防护研究所(意大利博洛尼亚)进行的研究的主要方面,以提供实用的解决方案(在使用和设计中),以H_p(3)评估ENEA TL肢体剂量计的响应)。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2011年第4期|p.187-191|共5页
  • 作者单位

    ENEA Radiation Protection Institute, Via dei Colli 16 1-40136, Bologna, Italy;

    ENEA Radiation Protection Institute, Via dei Colli 16 1-40136, Bologna, Italy;

    ENEA Radiation Protection Institute, Via dei Colli 16 1-40136, Bologna, Italy;

    ENEA Radiation Protection Institute, Via dei Colli 16 1-40136, Bologna, Italy;

    ENEA Radiation Protection Institute, Via dei Colli 16 1-40136, Bologna, Italy;

    ENEA Radiation Protection Institute, Via dei Colli 16 1-40136, Bologna, Italy;

    CEA, LIST, Laboratoire National Henri Becquerel (LNE LNHB), F-91191 Gif-sur-Yvette, France;

    CEA, LIST, Laboratoire National Henri Becquerel (LNE LNHB), F-91191 Gif-sur-Yvette, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号