Clinical studies using different imaging protocols to perform digital breast tomosynthesis (DBT) were reviewed (2008-14) to assess interpretive accuracy. Descriptive pooled statistics were used to estimate and summarise accuracy measures for each type of imaging protocol in relation to that of two-view full-field digital mammography (FFDM). In studies comparing multiple DBT imaging protocols, a trend of increased performance was often seen when including both the mediolateral oblique and craniocau-dal views for DBT alone and even more so for DBT adjunct to FFDM. Overall, the average ΔAUC (%; sd) across studies for stand-alone DBT (relative to FFDM), in one and in two views, were 2.2 (± 3.7) and 5.9 (± 4.6), and when used together with FFDM, 3.9 (± 2.0) and 6.7 (± 0.9). With respect to individual studies, improvements in accuracy using DBT were present for different types of imaging protocols although the magnitude of the impact varied between studies, and some studies did not show significant improvements in comparison with FFDM. The most consistent effect of improvement in breast cancer detection was seen across studies for two-view DBT with FFDM. These summary findings may depend on the sampling constraints present in tomosynthesis imaging and on other factors discussed in this paper. In order to investigate these effects more thoroughly and how they might impact outcomes, comparative or randomized-controlled trials are warranted.
机译:回顾(2008-14)使用不同成像方案进行数字化乳房断层合成(DBT)的临床研究,以评估解释的准确性。描述性汇总统计数据用于估计和总结每种图像协议相对于两视图全场数字乳房X线照片(FFDM)的准确性度量。在比较多种DBT成像方案的研究中,当仅包括DBT的中外侧斜视图和颅底视图同时包括FFDM的DBT时,通常会看到性能提高的趋势。总体而言,在一个视图和两个视图中,独立DBT(相对于FFDM)的各项研究的平均ΔAUC(%; sd)分别为2.2(±3.7)和5.9(±4.6),并且与FFDM一起使用时, 3.9(±2.0)和6.7(±0.9)。对于个别研究,尽管不同研究之间的影响程度有所不同,但对于不同类型的成像方案,使用DBT可以提高准确性,并且某些研究与FFDM相比没有显着改善。通过FFDM的双视图DBT的研究在乳腺癌检测中获得了最一致的改善效果。这些总结性发现可能取决于断层合成成像中存在的采样限制以及本文讨论的其他因素。为了更彻底地调查这些影响以及它们如何影响结果,有必要进行比较或随机对照试验。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2015年第4期|314-320|共7页
  • 作者

    T. M. Svahn; N. Houssami;

  • 作者单位

    School of Public Health, Sydney Medical School, University of Sydney, Sydney 2006, NSW, Australia;

    School of Public Health, Sydney Medical School, University of Sydney, Sydney 2006, NSW, Australia;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号