首页> 外文期刊>Radiation Protection Dosimetry >NON-VASCULAR INTERVENTIONAL PROCEDURES: EFFECTIVE DOSE TO PATIENT AND EQUIVALENT DOSE TO ABDOMINAL ORGANS BY MEANS OF DICOM IMAGES AND MONTE CARLO SIMULATION
【24h】

NON-VASCULAR INTERVENTIONAL PROCEDURES: EFFECTIVE DOSE TO PATIENT AND EQUIVALENT DOSE TO ABDOMINAL ORGANS BY MEANS OF DICOM IMAGES AND MONTE CARLO SIMULATION

机译:非血管介入手术:通过DICOM图像和蒙特卡罗模拟对腹部器官的有效剂量和等效剂量

获取原文
获取原文并翻译 | 示例
       

摘要

This study evaluates X-ray exposure in patient undergoing abdominal extra-vascular interventional procedures by means of Digital Imaging and Communications in Medicine (DICOM) image headers and Monte Carlo simulation. The main aim was to assess the effective and equivalent doses, under the hypothesis of their correlation with the dose area product (DAP) measured during each examination. This allows to collect dosimetric information about each patient and to evaluate associated risks without resorting to in vivo dosimetry. The dose calculation was performed in 79 procedures through the Monte Carlo simulator PCXMC (A PC-based Monte Carlo program for calculating patient doses in medical X-ray examinations), by using the real geometrical and dosimetric irradiation conditions, automatically extracted from DICOM headers. The DAP measurements were also validated by using thermoluminescent dosemeters on an anthropomorphic phantom. The expected linear correlation between effective doses and DAP was confirmed with an R~2 of 0.974. Moreover, in order to easily calculate patient doses, conversion coefficients that relate equivalent doses to measurable quantities, such as DAP, were obtained.
机译:这项研究通过医学数字成像和通信(DICOM)图像标题和蒙特卡洛模拟评估接受腹部血管外介入手术的患者的X射线暴露。主要目的是根据有效剂量和等效剂量与每次检查期间测得的剂量面积乘积(DAP)的相关性进行评估。这允许收集有关每个患者的剂量学信息并评估相关风险,而无需借助体内剂量学。通过使用自动从DICOM标头中提取的实际几何和剂量辐照条件,通过Monte Carlo仿真器PCXMC(基于PC的Monte Carlo程序,用于在医学X射线检查中计算患者剂量)以79个程序执行剂量计算。还通过在拟人体模上使用热发光剂量计验证了DAP的测量结果。有效剂量与DAP之间的预期线性相关性得到了证实,R〜2为0.974。而且,为了容易地计算患者剂量,获得了将等效剂量与可测量量(例如DAP)相关联的转换系数。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2016年第4期|509-515|共7页
  • 作者单位

    Post Graduate School of Medical Physics, Sapienza University of Rome, Rome, Italy;

    Post Graduate School of Medical Physics, Sapienza University of Rome, Rome, Italy;

    Post Graduate School of Medical Physics, Sapienza University of Rome, Rome, Italy;

    Post Graduate School of Medical Physics, Sapienza University of Rome, Rome, Italy;

    Department of Radiological Sciences, Vascular and Interventional Unit, Sapienza University of Rome, Rome, Italy;

    Department of Radiological Sciences, Vascular and Interventional Unit, Sapienza University of Rome, Rome, Italy;

    Department of Radiological Sciences, Vascular and Interventional Unit, Sapienza University of Rome, Rome, Italy;

    Department of Radiological Sciences, Vascular and Interventional Unit, Sapienza University of Rome, Rome, Italy;

    Department of Radiological Sciences, Vascular and Interventional Unit, Sapienza University of Rome, Rome, Italy;

    Department of Radiological Sciences, Health Physic Unit, Sapienza University of Rome, Rome, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-18 00:43:48

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号