首页> 外文期刊>Radiation Protection Dosimetry >RADIATION DOSE ESTIMATION BY COMPLETELY AUTOMATED INTERPRETATION OF THE DICENTRIC CHROMOSOME ASSAY
【24h】

RADIATION DOSE ESTIMATION BY COMPLETELY AUTOMATED INTERPRETATION OF THE DICENTRIC CHROMOSOME ASSAY

机译:通过完全自动解释Dicentric染色体测定的辐射剂量估算

获取原文
获取原文并翻译 | 示例

摘要

Accuracy of the automated dicentric chromosome (DC) assay relies on metaphase image selection. This study validates a software framework to find the best image selection models that mitigate inter-sample variability. Evaluation methods to determine model quality include the Poisson goodness-of-fit of DC distributions for each sample, residuals after calibration curve fitting and leave-one-out dose estimation errors. The process iteratively searches a pool of selection model candidates by modifying statistical and filter cut-offs to rank the best candidates according to their respective evaluation scores. Evaluation scores minimize the sum of squared errors relative to the actual radiation dose of the calibration samples. For one laboratory, the minimum score for the curve fit residual method was 0.0475 Gy~2, compared to 1.1975 Gy~2 without image selection. Application of optimal selection models using samples of unknown exposure produced estimated doses within 0.5 Gy of physical dose. Model optimization standardizes image selection among samples and provides relief from manual DC scoring, improving accuracy and consistency of dose estimation.
机译:自动化的DicEntric染色体(DC)测定的准确性依赖于中期图像选择。本研究验证了一个软件框架,以找到缓解样本互变性的最佳图像选择模型。测定模型质量的评估方法包括每个样品的DC分布的泊松良好,校准曲线拟合后残留物和留下一次剂量估计误差。该过程通过修改统计和滤波器截止,迭代地搜索选择模型候选池,以根据其各自的评估分数对最佳候选进行排名。评估得分最小化相对于校准样本的实际辐射剂量的平方误差之和。对于一个实验室,曲线拟合残余方法的最小分数为0.0475 Gy〜2,而无需图像选择1.1975 Gy〜2。使用未知曝光样本的最佳选择模型在物理剂量的0.5GY中产生的估计剂量。模型优化标准化样品中的图像选择,并从手动直流评分提供救济,提高剂量估算的准确性和一致性。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2019年第1期|42-47|共6页
  • 作者单位

    CytoGnomix Inc. POB 27052 60 N. Centre Rd London ON N5X 3X5 Canada;

    CytoGnomix Inc. POB 27052 60 N. Centre Rd London ON N5X 3X5 Canada;

    Health Canada Environmental and Radiation and Health Sciences Directorate Ottawa ON K1A 1C1 Canada;

    Canadian Nuclear Laboratories 286 Plant Rd Chalk River ON K0J 1 J0 Canada;

    CytoGnomix Inc. POB 27052 60 N. Centre Rd London ON N5X 3X5 Canada Department of Pathology and Laboratory Medicine University of Western Ontario 1151 Richmond St. London ON N6A 5C1 Canada;

    CytoGnomix Inc. POB 27052 60 N. Centre Rd London ON N5X 3X5 Canada Department of Biochemistry University of Western Ontario 1151 Richmond St. London ON N6A 5C1 Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);