首页> 外文期刊>Radiation Protection Dosimetry >OCCUPATIONAL EYE LENS DOSE ESTIMATED USING WHOLE-BODY DOSEMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY: A MONTE CARLO STUDY
【24h】

OCCUPATIONAL EYE LENS DOSE ESTIMATED USING WHOLE-BODY DOSEMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY: A MONTE CARLO STUDY

机译:职业眼睛镜片剂量在介入心脏病学和放射学中使用全身剂量表估计:蒙特卡罗研究

获取原文
获取原文并翻译 | 示例
           

摘要

Medical personnel performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. Reduction of the eye lens dose limit made its assessment in the interventional procedures one of the most challenging topics. The objective of this work is to assess eye lens doses based on the whole-body doses using methods of computational dosimetry. Assessment included different C-arm orientations (PA, LAO and RAO), tube voltages (80-110 kV) and efficiency of different combinations of protective equipment used in interventional procedures. Center position at the height of the thyroid gives best estimate of eye lens dose, with spreads of 11% (13%), 13% (17%) and 14% (13%) for the left (right) eye lens. The conversion factors of 1.03 (0.83), 1.28 (1.06) and 1.36 (1.06) to convert whole body to eye lens dose were derived for positions of first operator, nurse and radiographer, respectively. The eye lens dose reduction factors for different combinations of applied protective equipment are 178, 5 and 6, respectively.
机译:执行在心脏病学和放射介入手术的医务人员被认为是暴露于高剂量的电离辐射的专业组。眼镜剂量限制的减少在介入程序中进行了评估,其中一个最具挑战性主题之一。这项工作的目的是使用计算剂量测定方法评估基于全体剂量的眼睛镜片剂量。评估包括不同的C形臂方向(PA,老挝和RAO),管电压(80-110 kV)和介入程序中使用的保护设备的不同组合效率。甲状腺高度的中心位置可获得眼镜剂量的最佳估计,左(右)眼镜的11%(13%),13%(17%)和14%(13%)的差价。将整个身体转化为眼镜剂量的1.03(0.83),1.28(1.06)和1.36(1.06)的转换因子分别用于第一操作员,护士和上放大器的位置。用于应用保护设备的不同组合的眼镜剂量降低因子分别为178,5和6。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2019年第2期|135-142|共8页
  • 作者单位

    Univ Belgrade Dept Microelect & Tech Phys Sch Elect Engn Belgrade 11000 Serbia|Univ Belgrade Dept Radiat & Environm Protect Vinca Inst Nucl Sci Belgrade 11000 Serbia;

    Univ Belgrade Dept Microelect & Tech Phys Sch Elect Engn Belgrade 11000 Serbia|Univ Belgrade Dept Radiat & Environm Protect Vinca Inst Nucl Sci Belgrade 11000 Serbia;

    Univ Belgrade Dept Radiat & Environm Protect Vinca Inst Nucl Sci Belgrade 11000 Serbia;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);