首页> 外文期刊>Radiation Protection Dosimetry >OPTIMIZATION OF A RADIOPHOTOLUMINESCENT GLASS DOSEMETER FOR OCCUPATIONAL EYE LENS DOSIMETRY IN INTERVENTIONAL RADIOLOGY/CARDIOLOGY
【24h】

OPTIMIZATION OF A RADIOPHOTOLUMINESCENT GLASS DOSEMETER FOR OCCUPATIONAL EYE LENS DOSIMETRY IN INTERVENTIONAL RADIOLOGY/CARDIOLOGY

机译:介入放射学/心脏病学中用于职业眼镜片剂量的放射光致发光玻璃剂量仪的优化

获取原文
获取原文并翻译 | 示例
           

摘要

Hospital based workers that perform interventional radiology are at risk of reaching the eye lens dose limit of 20 mSv/y. These workers are exposed to the radiation scattered by the patient, which creates a complex field, with low radiation energy reaching the eyes of the medical staff from wide angles. Therefore, the dosemeter used in the assessment of the eye lens dose of interventional radiologists needs to respond accurately in such conditions. In this study, the angular response of a commercially available radiopho-toluminescent glass dosemeter, GD-352M, was optimized via Monte Carlo simulations, aiming at its use as eye lens dosemeter in interventional radiology. The improved dosemeter was manufactured and then characterized in terms of H-p(3), the quantity recommended for eye lens dosimetry. Its response was compared to the IEC 62387: 2012 requirements for H-p(3) and to requirements proposed specifically for eye lens dosemeters used in interventional radiology. The improved dosemeter meets the IEC 62387: 2012 requirements for energy and angular response for H-p(3) and also shows good agreement with the more strict requisites proposed for eye lens dosemeters to be used in interventional radiology.
机译:从事介入放射学的医院工作人员有可能达到20 mSv / y的晶状体剂量限制。这些工作人员暴露于患者散射的辐射下,这会形成一个复杂的场,低辐射能量会从广角到达医护人员的眼睛。因此,在这种情况下,用于评估介入放射科医生的晶状体剂量的剂量计需要准确响应。在这项研究中,通过蒙特卡洛模拟优化了市售的放射光致发光玻璃剂量计GD-352M的角响应,旨在将其用作介入放射学中的眼镜片剂量计。制造了改进的剂量计,然后根据H-p(3)(为眼镜片剂量法推荐的量)进行了表征。将其响应与针对H-p(3)的IEC 62387:2012要求以及专门针对介入放射学中的晶状体剂量计建议的要求进行了比较。改进的剂量计不仅满足IEC 62387:2012对H-p(3)的能量和角度响应的要求,而且与为介入放射学中使用的晶状体剂量计提出的更为严格的要求也显示出良好的一致性。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2018年第2期|177-183|共7页
  • 作者单位

    Chiyoda Technol Corp, Oarai Res Ctr, 3681 Narita Cho,Oarai Machi, Ibaraki 3111313, Japan;

    Belgian Nucl Res Ctr, Boeretang 200, B-2400 Mol, Belgium;

    Vrije Univ Brussel, Univ Ziekenhuis, Laarbeeklaan 103, B-1090 Brussels, Belgium;

    Minist Educ Brazil, CAPES Fdn, BR-70040020 Brasilia, DF, Brazil;

    Vrije Univ Brussel, Dept Radiat Protect, Laarbeeklaan 103, B-1090 Brussels, Belgium;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);