首页> 外文期刊>Radiation Protection Dosimetry >ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY
【24h】

ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY

机译:眼透镜剂量的光致发光玻璃剂量仪的能量和角依赖性

获取原文
获取原文并翻译 | 示例

摘要

Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radio-photoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0 up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK·CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruder Boskovic Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to H_p(3), although some improvements may be necessary.
机译:最近的研究表明,晶状体混浊可以在比以前接受的更低的辐射剂量下发生。鉴于这些研究,国际放射防护委员会于2011年建议将眼镜剂量限值从150 mSv / y降低至20 mSv / y。这意味着需要监视眼镜片接收的剂量。在这项研究中,小棒放射光致发光玻璃剂量计(GD-300系列;日本AGC)的能量(ISO 4037 X射线窄谱系列,S-Cs和S-Co)和角度依赖性( 0至90度,使用2种ISO能量:N-60和S-Cs。所有采集都是在SCK·CEN比利时使用ORAMED提出的圆柱体模进行的。对于选定的能量(N-60,N-80,N-100,N-120和N-250),将在Ruder Boskovic研究所(克罗地亚)的ISO水平板体模上辐照的剂量计的响应与辐照后的辐照进行了比较。在圆柱体上。相对于S-C,GD-300系列在圆柱体模型上显示出良好的能量依赖性。从0到45度,无论是垂直放置还是水平放置在圆柱体模上,剂量计都没有明显的角度依赖性。但是,在较高角度下,观察到一些角度相关性,主要是当剂量计用低能光子(N-60)照射时。结果表明,尽管可能需要改进,但GD-300系列具有与H_p(3)相关的良好性能。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2016年第4期|208-212|共5页
  • 作者单位

    Belgian Nuclear Research Centre (SCK-CEN), Boeretang 200, 2400 Mol, Belgium ,Vrije Universiteit Brussel (VUB), LABO and BEFY, Laarbeeklaan 103, 1090 Brussels, Belgium ,CAPES Foundation, Ministry of Education of Brazil, Brasilia, DF 70040-020, Brazil;

    Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb, Croatia;

    Belgian Nuclear Research Centre (SCK-CEN), Boeretang 200, 2400 Mol, Belgium;

    Vrije Universiteit Brussel (VUB), LABO and BEFY, Laarbeeklaan 103, 1090 Brussels, Belgium ,Department of Radiation Protection (VUB), Laarbeeklaan 103, 1090 Brussels, Belgium;

    Oarai Research Center, Chiyoda Technol Corporation, 3681 Naritacho, Oarai-machi, Higashiibaraki-gun, Ibaraki 311-1313, Japan;

    Belgian Nuclear Research Centre (SCK-CEN), Boeretang 200, 2400 Mol, Belgium;

    Vrije Universiteit Brussel (VUB), LABO and BEFY, Laarbeeklaan 103, 1090 Brussels, Belgium ,Department of Radiology, UZ Brussel, Laarbeeklaan 101, 1090 Brussels, Belgium;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号