首页> 外文期刊>Radiation measurements >Eye lens dosimetry for workers at Fukushima Daiichi Nuclear Power Plant-1: Laboratory study on the dosemeter position and the shielding effect of full face mask respirators
【24h】

Eye lens dosimetry for workers at Fukushima Daiichi Nuclear Power Plant-1: Laboratory study on the dosemeter position and the shielding effect of full face mask respirators

机译:福岛达核电站工人的眼镜剂量测定法 - 1:对剂量仪位置的实验室研究和全面面膜呼吸器的屏蔽效果

获取原文
获取原文并翻译 | 示例
           

摘要

We conducted an eye lens dosimetry study on workers, engaged in recovery and decommissioning operations at Fukushima Daiichi Nuclear Power Station. To investigate the optimal positioning of eye lens dosemeters and the shielding effect of full face mask respirators, photon irradiation experiments to various eye lens dosemeters attached to a head phantom were performed at the secondary photon calibration fields of the Japan Atomic Energy Agency. As a result, no marked difference was observed in readings of the dosemeters attached to the different positions on the head phantom. Moreover, two types of full face mask respirators provided an insignificant shielding effect from photons of 83-662 keV. Comparative measurements between AP and ROT geometries suggested that head-mounted dosemeters would generally produce a small angular variation in readings specifically in multidirectional fields as compared to the torso-mounted dosemeters.
机译:我们对工人进行了一项眼镜剂量测定研究,从事福岛达奇核电站的恢复和退役业务。 为了研究眼镜剂量仪的最佳定位和全面掩模呼吸器的屏蔽效果,在日本原子能机构的二次光子校准领域进行了附着在头部模型的各种眼睛镜仪的光子辐射实验。 结果,在连接到头部幻影上的不同位置的剂量仪的读数中没有观察到明显的差异。 此外,两种类型的全面罩呼吸器提供了来自83-662 kev的光子的微不足道的屏蔽效果。 与躯干安装的称位仪相比,AP和腐烂几何形状之间的比较测量表明,头部安装的剂量仪通常将在多向字段中专门的读数产生小的角度变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号