首页> 外文期刊>Radiation Protection Dosimetry >INTERVENTIONAL RADIOLOGICAL PROCEDURES MOST PRONE TO CAUSE HIGH PATIENT PEAK SKIN DOSES BASED ON REVIEW OF 7607 PROCEDURES
【24h】

INTERVENTIONAL RADIOLOGICAL PROCEDURES MOST PRONE TO CAUSE HIGH PATIENT PEAK SKIN DOSES BASED ON REVIEW OF 7607 PROCEDURES

机译:根据对7607程序的审查,介入放射学程序最容易引起高峰值皮肤病剂量

获取原文
获取原文并翻译 | 示例

摘要

Peak skin doses to patients undergoing interventional radiological procedures in a 3-year period were assessed to identify the most critical procedures and evaluate probability for occurrence of radiation-induced tissue injuries. Data of 7607 patients were reviewed, identifying those with cumulative air kerma at a reference point (K-a,K-r) exceeding 3 Gy. Observed tissue injuries in patients with exceeded levels were gathered by a questionnaire. K-a,K-r exceeded 3 Gy in 145 patients, all during vascular procedures; most frequently in preparations for liver radioembolization (SIRT), transjugular intrahepatic portosystemic shunt (TIPS), endovascular abdominal aortic repair (EVAR), adrenal venous sampling (AVS), endovascular thoracic aortic repair (TEVAR) and embolizations in abdominal/pelvic area (30, 21.4, 13.4, 12.6, 9.6 and 3.5% of patients, respectively). A total of 10 patients, extrapolating to similar to 0.6% of all patients, reported tissue injuries. During interventional radiological procedures threshold for radiation-induces tissue injuries can be exceeded in a significant number of patients (1.9%). Tissue injuries were reported approximately three times less frequently than anticipated; their severity was poorly related to those expected.
机译:评估了在3年中接受放射介入治疗的患者的皮肤峰值剂量,以确定最关键的过程并评估发生放射诱发的组织损伤的可能性。审查了7607例患者的数据,确定在参考点(K-a,K-r)超过3 Gy的累积空气比释动能。通过问卷收集超过水平患者的观察到的组织损伤。 145名患者的K-a,K-r在血管手术期间均超过3 Gy;最常用于肝放射栓塞(SIRT),经颈静脉肝内门体分流术(TIPS),血管内腹主动脉修复(EVAR),肾上腺静脉采样(AVS),血管内胸主动脉修复(TEVAR)和腹腔/盆腔区域栓塞的准备中(30 ,分别为21.4、13.4、12.6、9.6和3.5%的患者)。共有10位患者报告了组织损伤,据推测约占所有患者的0.6%。在介入放射学过程中,大量患者(1.9%)可能超过放射线引起的组织损伤的阈值。报告的组织损伤频率比预期的少大约三倍;它们的严重程度与预期的严重程度关系不大。

著录项

  • 来源
    《Radiation Protection Dosimetry 》 |2019年第3期| 319-325| 共7页
  • 作者单位

    UMC Ljubljana Clin Radiol Inst Zaloska 7 Ljubljana 1000 Slovenia;

    Inst Occupat Safety Chengdujska 25 Ljubljana 1260 Slovenia;

    Minist Hlth Slovenian Radiat Protect Adm Ajdovscina 4 Ljubljana 1000 Slovenia;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng