首页> 外文期刊>Radiation Protection Dosimetry >VALIDATION OF MONTE CARLO DOSE CALCULATION FOR PAEDIATRIC CT EXAMINATIONS USING TUBE CURRENT MODULATION BASED ON IN-PHANTOM DOSIMETRY
【24h】

VALIDATION OF MONTE CARLO DOSE CALCULATION FOR PAEDIATRIC CT EXAMINATIONS USING TUBE CURRENT MODULATION BASED ON IN-PHANTOM DOSIMETRY

机译:基于幻影剂量的管电流调制对小儿CT检查的蒙特卡洛剂量计算的验证

获取原文
获取原文并翻译 | 示例

摘要

The aim of this study is to estimate tube current modulation (TCM) profiles in paediatric computed tomography (CT) examinations with a TCM scheme (Volume-EC) and evaluate the estimation accuracy of TCM profiles. Another aim is to validate organ doses calculated using Monte Carlo-based CT dosimetry software and estimated TCM profiles by comparing them with those measured using 5-year-old and 10-year-old anthropomorphic phantoms and radio-photoluminescence glass dosemeters. Dose calculations were performed by inputting detailed descriptions of a CT scanner, scan parameters and CT images of the phantoms into the software. Organ doses were evaluated from the calculated dose distribution images. Average relative differences (RDs) between the estimated and actual TCM profiles ranged from -3.6 to 5.6%. RDs between the calculated and measured organ doses ranged from -4.2 to 13.0% and -18.1 to 4.9% for 5-year-old and 10-year-old phantoms, respectively. These results validate dose calculations for paediatric CT scans using TCM.
机译:这项研究的目的是通过TCM方案(Volume-EC)估计小儿计算机X线检查(CT)检查中的管电流调制(TCM)曲线,并评估TCM曲线的估计准确性。另一个目标是通过将其与使用5岁和10岁拟人化体模和放射光致发光玻璃剂量计测量的器官剂量进行比较,来验证使用基于Monte Carlo的CT剂量学软件计算的器官剂量和估算的TCM轮廓,以验证它们的有效性。通过将CT扫描仪的详细说明,体模的扫描参数和CT图像输入软件,进行剂量计算。从计算的剂量分布图像评估器官剂量。估计和实际TCM分布之间的平均相对差异(RD)为-3.6至5.6%。对于5岁和10岁的幻影,计算和测量的器官剂量之间的RD分别为-4.2至13.0%和-18.1至4.9%。这些结果验证了使用中医进行儿科CT扫描的剂量计算。

著录项

  • 来源
    《Radiation Protection Dosimetry 》 |2018年第4期| 508-517| 共10页
  • 作者单位

    Nagoya Univ, Dept Radiol Sci, Grad Sch Med, Higashi Ku, 1-1-20 Daikominami, Nagoya, Aichi, Japan|Natl Canc Ctr Hosp East, Dept Radiol Technol, 6-5-1 Kashiwanoha, Kashiwa, Chiba, Japan|Natl Inst Quantum & Radiol Sci & Technol, Natl Inst Radiol Sci, Dept Radiat Measurement & Dose Assessment, Inage Ku, 4-9-1 Anagawa, Chiba, Japan;

    Natl Canc Ctr Hosp East, Dept Radiol Technol, 6-5-1 Kashiwanoha, Kashiwa, Chiba, Japan;

    Natl Canc Ctr Hosp East, Dept Radiol Technol, 6-5-1 Kashiwanoha, Kashiwa, Chiba, Japan;

    Natl Inst Quantum & Radiol Sci & Technol, Natl Inst Radiol Sci, Dept Radiat Measurement & Dose Assessment, Inage Ku, 4-9-1 Anagawa, Chiba, Japan;

    Canon Med Syst Corp, 1385 Shimoishigami, Otawara, Tochigi, Japan;

    Natl Inst Quantum & Radiol Sci & Technol, Natl Inst Radiol Sci, Dept Radiat Measurement & Dose Assessment, Inage Ku, 4-9-1 Anagawa, Chiba, Japan;

    Natl Canc Ctr Hosp East, Dept Radiol Technol, 6-5-1 Kashiwanoha, Kashiwa, Chiba, Japan;

    Canon Med Syst Corp, 1385 Shimoishigami, Otawara, Tochigi, Japan;

    Natl Canc Ctr Hosp East, Dept Diagnost Radiol, 6-5-1 Kashiwanoha, Kashiwa, Chiba, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词