Dialysis system is an artificial medical operating system that works as a kidney in the human body, and is used when the kidney has failed or has been spoiled. In this study, reliability and maintainability analysis, which are of the fundamental issues for the operation management of a dialysis system, was developed. Descriptive statistics of all the failures at each device of the system were determined. The failure data covers a period of 45 months. The best fit of the failure data between the common theoretical distributions was found, and the respective parameters were identified. Moreover, the reliability and the maintainability at device and system level for different time intervals were calculated. They both proved to be useful tools to assess the current situation, and to predict reliability, mainly in the short term, for upgrading the operation management of the system.
机译:透析系统是一种人造医学操作系统,可以在人体中充当肾脏,并在肾脏衰竭或变质时使用。在这项研究中,开发了可靠性和可维护性分析,这是透析系统运行管理的基本问题。确定了系统每个设备上所有故障的描述性统计信息。故障数据涵盖45个月。找到常见理论分布之间的故障数据的最佳拟合,并确定了各个参数。此外,还计算了不同时间间隔在设备和系统级别的可靠性和可维护性。事实证明,它们都是评估当前情况和预测可靠性的有用工具,主要是在短期内,用于升级系统的运行管理。