首页> 外文期刊>日本建築学会构造系論文集 >あと施工アンカーによる直線定着主筋を有するRC壁柱状部材の履歴復元力特性
【24h】

あと施工アンカーによる直線定着主筋を有するRC壁柱状部材の履歴復元力特性

机译:后安装锚杆直接锚固主筋的钢筋混凝土墙柱构件的滞后恢复力特性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper describes investigation about hysteretic restoring force characteristics of reinforced concrete specimens. Static loading tests of three specimens were conducted. One of them was normal reinforced concrete specimen, while in the other specimens, post-installed adhesive anchors were used for main bar anchorages. The difference between the two was anchor length for main bars. Three specimens had almost same load capacity. Though, the energy dissipation characteristics were different for each other. The specimen which had shorter length of anchorage had lowest capacity in energy dissipation. Nonlinear finite element analysis were conducted. The analytical results corresponded well to the test results.%本報では,あと施工アンカーを用いたRC造壁柱状部材試験体の 実験概要とともに,実験を対象として実施した非線形FEM解析に ついて述べた。解析では,あと施工アンカーと在来工法の違いを付 着特性の設定方法の違いにより再現することを試みた。付着強度は コンクリート強度により定め,互いに等しいものとする一方で,コ ンクリート境界面の周長の違いをモデルに反映した。すなわち,あ と施工アンカーの場合は,穿孔径を用いることにより,鉄筋周長よ りも大きな付着面積を有するモデルとした。さらに,解析結果を実 験結果と比較検討した結果,以下の知見が得られた。
机译:本文介绍了钢筋混凝土标本的滞后恢复力特性研究,对三个标本进行了静载荷试验,其中一个是普通钢筋混凝土标本,而在其他标本中,后安装胶锚被用作主钢筋锚固。两者之间的区别在于主筋的锚固长度。三个试件的承载能力几乎相同。据认为,能量耗散特性彼此不同;锚固长度较短的试件的能量耗散能力最低。非线性有限元在此报告中,描述了使用后安装锚杆的钢筋混凝土墙柱形构件标本的实验大纲以及对该实验进行的非线性有限元分析。 ..在分析中,我们试图通过安装特性的设置方法上的差异来重现后安装锚与传统施工方法之间的差异。粘结强度由混凝土强度决定,并且彼此相等,而混凝土界面的周长差异则反映在模型中。即,在新构造的锚固件的情况下,通过使用钻孔直径,使用附接面积比钢筋的周长大的模型。此外,将分析结果与实验结果进行比较,得到以下发现。