首页> 外文期刊>Practice periodical on structural design and construction >Tensile Strength Improvement of Concrete Slabs Using Polyurea Spray
【24h】

Tensile Strength Improvement of Concrete Slabs Using Polyurea Spray

机译:使用聚脲喷雾混凝土板的拉伸强度改善

获取原文
获取原文并翻译 | 示例
           

摘要

Ductility is a desirable trait in an otherwise brittle concrete which is conventionally achieved via methods like introduction of steel reinforcement. While thin spray-on liner (TSL) is a material used in underground support systems to enhance the strength and ductility of rock and shotcrete, its application in concrete is a promising prospect. The study in this paper was conducted to observe the effect of application of Polyurea TSL on the flexural properties of unreinforced and lightly reinforced concrete slabs of varying strengths applied with varying thicknesses of Polyurea. The study used three-point flexural tests on slabs of uniform dimensions, simply supported on all sides, until failure or limit of test setup. Deflection was measured underneath the slab midpoint via a linear displacement sensor. Comparative analysis indicated that for the same strength and steel reinforcement, Polyurea application was significantly associated with an increase in stiffness, peak load, yield load, ductility, and energy dissipation in the specimens. Increasing Polyurea thickness also produced the same trend in the observed parameters.
机译:延展性是诸如脆性混凝土中的理想特征,其通常通过钢筋引入等方法实现。虽然薄的喷涂衬垫(TSL)是在地下支撑系统中使用的材料,以增强岩石和吸收的强度和延展性,其在混凝土中的应用是一个有希望的前景。本文的研究进行了观察到聚脲TSL应用对不同厚度的不同强度的未原强度和轻质钢筋混凝土板弯曲性能的影响。该研究使用了三分弯曲试验在均匀尺寸的平板上,只需在所有侧面都支撑,直到测试设置的故障或限制。通过线性位移传感器在板坯中点下方测量偏转。对比分析表明,对于相同的强度和钢筋,对于刚度,峰值负荷,屈服负荷,延展性和试样的能量耗散显着相关。增加的聚脲厚度也在观察到的参数中产生了相同的趋势。

著录项

  • 来源
    《Practice periodical on structural design and construction》 |2021年第1期|04020048.1-04020048.12|共12页
  • 作者单位

    Dept. of Structural Engineering Military College of Engineering National Univ. of Sciences and Technology Risalpur 23200 Pakistan;

    Dept. of Structural Engineering Military College of Engineering National Univ. of Sciences and Technology Risalpur 23200 Pakistan;

    Dept. of Mechatronics Engineering College of Electrical and Mechanical Engineering National Univ. of Sciences and Technology Islamabad 44000 Pakistan;

    Dept. of Structural Engineering Military College of Engineering National Univ. of Sciences and Technology Risalpur 23200 Pakistan;

    Dept. of Structural Engineering Military College of Engineering National Univ. of Sciences and Technology Risalpur 23200 Pakistan;

    Dept. of Structural Engineering Military College of Engineering National Univ. of Sciences and Technology Risalpur 23200 Pakistan;

    Dept. of Structural Engineering Military College of Engineering National Univ. of Sciences and Technology Risalpur 23200 Pakistan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Concrete slabs; Flexural strength; Polyurea; Tensile strength; Thin spray-on liner;

    机译:混凝土板;抗弯强度;聚脲;抗拉强度;薄喷涂衬垫;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号