首页> 外文期刊>Nordic pulp and paper research journal >Quantitative analysis of synthetic sizing agents (ASA/AKD) using NIR spectroscopy
【24h】

Quantitative analysis of synthetic sizing agents (ASA/AKD) using NIR spectroscopy

机译:使用NIR光谱对合成上浆剂(ASA / AKD)进行定量分析

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this work was to develop a fast and easy-to-use method for the quantification of synthetic sizing agents. The investigations have shown that a quantitative determination of synthetic sizing agents (ASA/AKD) is possible using NIR spectroscopy. With the help of multivariate data analysis and PLS regression, mainly the region of the CH_2-bands around 4300 cm~(-1) and 5750 cm~(-1) are evaluated. The prediction error (RMSEP) for the determination of AKD is 0.01 % and 0.013% for ASA both calibrated for a copy paper system. Even an analysis of the percentage of bound and unbound ASA/AKD is possible by NIR spectroscopy of extracted paper samples. Thus, a fast and detailed investigation of mechanisms as regards sizing is possible. It has been shown that sizing agents adsorbed onto fillers do not significantly affect the water absorption (penetration) but they can increase the surface hydrophobicity (wetting). However, sizing agents adsorbed at highly anionic polyelectrolytes can contribute to (internal) sizing to a large extent, when they are retained in the paper. The percentage of extractable ASA depends mainly on the used solvent. The best extraction yields were obtained with polar solvents, such as acetone or methanol. There is a good correlation between the sizing level and the extracted amount of sizing agent, thus showing that extractable (not-bound) ASA contributes to sizing to a large extent and that the formation of ester bonds with the cellulose plays a lesser role in the development of sizing. The determination of sizing agents using NIR spectroscopy might even be available as an online application for the pulp and paper industry.
机译:这项工作的目的是开发一种快速,易于使用的定量上浆剂的方法。研究表明,使用NIR光谱法可以定量测定合成上浆剂(ASA / AKD)。借助多元数据分析和PLS回归,主要评估了CH_2波段在4300 cm〜(-1)和5750 cm〜(-1)附近的区域。对于ASA都确定了AKD的预测误差(RMSEP)为0.01%和0.013%,这两个都是针对复印纸系统校准的。甚至可以通过NIR光谱分析提取的纸样来分析结合和未结合ASA / AKD的百分比。因此,可以对尺寸进行快速而详细的研究。已经表明,吸附在填料上的上浆剂不会显着影响吸水率(渗透率),但会增加表面疏水性(润湿)。但是,当吸附在高度阴离子聚电解质上的施胶剂保留在纸中时,它们在很大程度上有助于(内部)施胶。可萃取ASA的百分比主要取决于所用溶剂。使用极性溶剂(例如丙酮或甲醇)可获得最佳的提取率。上浆水平和上浆剂的提取量之间具有良好的相关性,因此表明可萃取(未结合)的ASA在很大程度上有助于上浆,并且与纤维素形成酯键的作用较小。上浆的发展。使用NIR光谱测定上浆剂甚至可以作为纸浆和造纸行业的在线应用程序使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号