首页> 外文期刊>Applied Spectroscopy: Society for Applied Spectroscopy >Fast and Environmentally Friendly Quantitative Analysis of Active Agents in Anti-Diabetic Tablets by an Alternative Laser-Induced Breakdown Spectroscopy (LIBS) Method and Comparison to a Validated Reversed-Phase High-Performance Liquid Chromatography (RP -HPLC) Method
【24h】

Fast and Environmentally Friendly Quantitative Analysis of Active Agents in Anti-Diabetic Tablets by an Alternative Laser-Induced Breakdown Spectroscopy (LIBS) Method and Comparison to a Validated Reversed-Phase High-Performance Liquid Chromatography (RP -HPLC) Method

机译:通过替代的激光诱导击穿光谱法(LIBS)和与已验证的反相高效液相色谱法(RP -HPLC)进行比较,快速,环保地对抗糖尿病片剂中的活性剂进行定量分析

获取原文
获取原文并翻译 | 示例
           

摘要

Laser-induced breakdown spectroscopy (LIBS) is evaluated as a potential analytic technique for rapid screening and quality control of anti-diabetic tablets. This paper proposes a simple LIBS-based method for the quantitative analysis of two active pharmaceutical ingredients (APIs): metformin (Met) and glybenclamide (Gly). In order to quantify both APIs, chlorine (CI) concentration was estimated by employing the Cl/Br optical emission ratio, where Br was introduced as internal standard. Calibration curves were prepared, achieving linearity higher than 99%. On the other hand, for comparison to the proposed method, an isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method was also developed for quantitative determination of the same analytes by ultraviolet (UV) detection. The chromatographic separation was achieved on a Phenomenex Hypersil C18, 250 mm × 4.6 mm, 5 μm column. The mobile phase was K_2HPO_4/H_3PO_4-CH_3OH and flow rate was 1.0 mL min~(-1). The method is linear over a range of 10-60 μg mL~(-1) for Gly and 5-30 μg mL~(-1) for Met and the correlation coefficients were ≥0.99. Recoveries were found to be in the range of 95-101%. Furthermore, four different commercial brands of each active agent were evaluated by both proposed LIBS and chromatographic methods and results were compared with each other. The comparison was satisfactorily validated by analysis of variance (ANOVA).
机译:激光诱导击穿光谱法(LIBS)被评估为快速筛选和控制抗糖尿病药的质量控制的潜在分析技术。本文提出了一种基于LIBS的简单方法,用于定量分析两种活性药物成分(API):二甲双胍(Met)和糖基苯甲酰胺(Gly)。为了量化这两种API,通过采用Cl / Br的光发射比来估算氯(CI)浓度,其中将Br作为内标引入。制备了校准曲线,线性度高于99%。另一方面,为了与提出的方法进行比较,还开发了等度反相高效液相色谱(RP-HPLC)方法,用于通过紫外(UV)检测定量测定相同的分析物。色谱分离是在Phenomenex Hypersil C18、250 mm×4.6 mm,5μm色谱柱上完成的。流动相为K_2HPO_4 / H_3PO_4-CH_3OH,流速为1.0 mL min〜(-1)。该方法在Gly的10-60μgmL〜(-1)和Met的5-30μgmL〜(-1)范围内是线性的,相关系数≥0.99。发现回收率在95-101%的范围内。此外,通过提议的LIBS和色谱方法对每种活性剂的四个不同商业品牌进行了评估,并将结果进行了比较。通过方差分析(ANOVA)令人满意地验证了该比较。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号