An investigation is made of the use of long, slit-like windows in the wall of a rectangular, tunnel-entrance hood to suppress the harmful environmental impact of the compression wave produced as a high-speed train enters a long tunnel. Model scale testing and numerical simulation indicate that when the cross-sectional area of the hood is larger than that of the tunnel, optima reduction in the maximum compression wave pressure gradient is achieved when the width of the slit window decreases inwards from the hood entrance, and when total length of the slit is no more than about 80% of the hood length.
机译:已经进行了研究,在矩形的隧道入口罩的壁上使用狭长的类似狭缝的窗户,以抑制高速列车进入长隧道时产生的压缩波对环境的有害影响。模型规模测试和数值模拟表明,当机罩的横截面面积大于隧道的横截面时,当狭缝窗口的宽度从机罩入口向内减小时,最大压缩波压力梯度将达到最佳减小,当狭缝的总长度不超过烟罩长度的80%时。