首页> 外文期刊>NDT & E international >Nondestructive evaluation of micro-cracks in a ceramic ferrule by resonant ultrasound spectroscopy
【24h】

Nondestructive evaluation of micro-cracks in a ceramic ferrule by resonant ultrasound spectroscopy

机译:共振超声光谱法无损评估陶瓷套管中的微裂纹

获取原文
获取原文并翻译 | 示例
       

摘要

We performed a nondestructive evaluation of micro-cracks in ceramic ferrules for optical fiber connectors by resonant ultrasound spectroscopy (RUS). The ferrules were cylinders 10 mm in length and 2.5 mm in diameter. The acceptable ferrules had no cracks or ones below 5 mu m and the defective ferrules had cracks from 5 to 25 mu m in length. The acceptable ferrules could be distinguished from the defective ones statistically, even those with cracks of 5 mu m, by comparing the differences between the resonant frequencies for both specimens.
机译:我们通过共振超声光谱(RUS)对用于光纤连接器的陶瓷插芯中的微裂纹进行了无损评估。套圈是长度为10毫米,直径为2.5毫米的圆柱体。合格的插芯没有裂纹或小于5微米的裂纹,次品的插芯长度为5至25微米。通过比较两个样品的共振频率之间的差异,可以从统计学上将合格的密封垫圈与有缺陷的密封垫圈区别开来,即使是裂纹为5微米的密封垫圈也是如此。