This work aims at presenting the detection and diagnosis of electrical faults in the stator winding of three-phase induction motors using magnetic flux and vibration analysis techniques. A relationship was established between the main electrical faults (inter-turn short circuits and unbalanced voltage supplies) and the signals of magnetic flux and vibration, in order to identify the characteristic frequencies of those faults. The experimental results showed the efficiency of the conjugation of these techniques for detection, diagnosis and monitoring tasks. The results were undoubtedly impressive and can be adapted and used in real predictive maintenance programs in industries.
机译:这项工作旨在介绍利用磁通量和振动分析技术检测和诊断三相感应电动机定子绕组中的电气故障。在主要电气故障(匝间短路和不平衡电压源)与磁通量和振动信号之间建立了关系,以便识别这些故障的特征频率。实验结果表明,将这些技术结合在一起用于检测,诊断和监视任务的效率。结果无疑是令人印象深刻的,可以在行业中的实际预测性维护计划中进行调整和使用。