首页> 外文期刊>Materials Evaluation >Acoustic Emission Response of 18% Ni Maraging Steel Weldment with Inserted Cracks of Varying Depth to Thickness Ratio
【24h】

Acoustic Emission Response of 18% Ni Maraging Steel Weldment with Inserted Cracks of Varying Depth to Thickness Ratio

机译:18%Ni马氏体时效钢焊缝的声发射响应,随深度和厚度比的变化而插入裂缝

获取原文
获取原文并翻译 | 示例
       

摘要

Acoustic emission studies have been carried out on a batch of welded and centre cracked specimens made of 18% Ni M250 maraging steel where the crack depth to specimen thickness ratio varied from approximately 10/80 to 25/80. Broad band AE transducers providing maximum sensitivity in frequency range 135 to 310 KHz were used for the AE monitoring. The paper brings out the AE performance of the specimens with inserted surface cracks of different sizes when the latter become critically severe leading to failure. The studies indicate the prediction possibility for the hardware constructed out of this material reasonably well before their final rupture. The AE signatures are also presented in a form that would facilitate generation of an acceptance criteria for the evaluation of hardware in real time.
机译:对一批由18%Ni M250马氏体时效钢制成的焊接和中心开裂的试样进行了声发射研究,试样的开裂深度与试样厚度之比在10/80至25/80之间变化。在135到310 KHz频率范围内提供最大灵敏度的宽带AE传感器用于AE监视。当插入的不同尺寸的表面裂纹变得非常严重而导致失效时,本文展示了带有不同尺寸的表面裂纹的试样的AE性能。研究表明,用这种材料制成的硬件在最终破裂之前的预测可能性相当合理。 AE签名还以有助于实时生成用于硬件评估的验收标准的形式提供。