首页> 外文期刊>Journal of Thermophysics and Heat Transfer >Performance Analysis of an Electrostatic Switched Radiator Using Heat-Flux-Based Emissivity Measurement
【24h】

Performance Analysis of an Electrostatic Switched Radiator Using Heat-Flux-Based Emissivity Measurement

机译:基于热通量辐射率测量的静电开关散热器的性能分析

获取原文
获取原文并翻译 | 示例
       

摘要

The heat-flux-based emissivity measurement technique developed in our earlier work has been used to study the performance of an electrostatic switched radiator. The capability of fast and accurate measurement of the real-time changes in emissivity enabled by this technique allowed understanding of the transient behavior during activation, as well as identification of a major failure mode of the second-generation electrostatic radiator. A solution for resolution of this failure mode was then proposed and successfully tested, producing accurate and repeatable results over many cycles. A change in emissivity of 0.52 was achieved with 280 V applied, among the best consistent results achieved through electrostatic technology. The current work offers further understanding of electrostatic radiator performance and its application to space vehicles.
机译:我们在早期工作中开发的基于热通量的发射率测量技术已用于研究静电开关散热器的性能。通过此技术可以快速准确地测量发射率的实时变化,从而可以了解激活期间的瞬态行为,并可以识别第二代静电散热器的主要故障模式。然后,提出了解决该故障模式的解决方案并成功进行了测试,从而在许多周期内都能产生准确且可重复的结果。施加280 V电压可实现0.52的发射率变化,这是通过静电技术获得的最佳一致性结果。当前的工作进一步了解了静电辐射器的性能及其在航天器中的应用。