首页> 外文期刊>Journal of Materials Research >Assessment of single-fiber fragmentation using scanning acoustic microscopy
【24h】

Assessment of single-fiber fragmentation using scanning acoustic microscopy

机译:使用扫描声学显微镜评估单纤维破碎

获取原文
获取原文并翻译 | 示例
       

摘要

Scanning acoustic microscopy (SAM) was used to obtain the critical fragmentation length of a 7-mu m-diameter carbon fiber embedded in an optically transparent epoxy matrix and was subjected to a standard fiber fragmentation test. The SAM-assessed critical fragmentation length of 356 ± 59.5 μm compared favorably with the value 341 ± 52.3 μm obtained independently from commonly used photoelastic techniques. Additionally, the SAM images allowed an assessment of regions of fiber-matrix debond, including the measurement of an average debond of 61.0 ± 11.8 μm along the fiber from the fragment ends, which could not be obtained with photoelastic methods. The application of SAM to the assessment of optically opaque composite materials is explained in this paper.
机译:使用扫描声显微镜(SAM)获得嵌入在光学透明环氧树脂基质中的7微米直径碳纤维的临界断裂长度,并进行了标准的纤维断裂测试。 SAM评估的临界断裂长度为356±59.5μm,与从常用光弹性技术独立获得的值341±52.3μm相比具有优势。此外,SAM图像还可以评估纤维基质的脱胶区域,包括沿纤维从碎片末端测得的平均脱胶率为61.0±11.8μm,这是光弹性方法无法获得的。本文介绍了SAM在光学不透明复合材料评估中的应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号