...
首页> 外文期刊>Journal of food engineering >High-pressure destruction kinetics of Clostridium sporogenes ATCC 11437 spores in milk at elevated quasi-isothermal conditions
【24h】

High-pressure destruction kinetics of Clostridium sporogenes ATCC 11437 spores in milk at elevated quasi-isothermal conditions

机译:准等温条件下牛奶中产孢梭状芽孢杆菌ATCC 11437孢子的高压破坏动力学

获取原文
获取原文并翻译 | 示例
           

摘要

The high-pressure sterilization establishment requires data on isobaric and isothermal destruction kinetics of baro-resistant pathogenic and spoilage bacterial spores. In this study, Clostridium sporogenes 11437 spores (10~7 CFU/ml) inoculated in milk were subjected to different pressure, temperature and time (P, T, t) combination treatments (700-900 MPa; 80-100 ℃; 0-32 min). An insulated chamber was used to enclose the test samples during the treatment for maintaining isobaric and quasi-isothermal processing conditions. Decimal reduction times (D values) and pressure and temperature sensitivity parameters, Z_T (pressure constant) and Z_P (temperature constant) were evaluated using a 3 × 3 full factorial experimental design. HP treatments generally demonstrated a minor pressure pulse effect (PE) (no holding time) and the pressure hold time effect was well described by the first order model (R~2 > 0.90). Higher pressures and higher temperatures resulted in a higher destruction rate and a higher microbial count reduction. At 900 MPa, the temperature corrected D values were 9.1, 3.8, 0.73 min at 80, 90, 100 ℃, respectively. The thermal treatment at 0.1 MPa resulted in D values 833, 65.8, 26.3, 6.0 min at 80, 90, 95, 100℃ respectively. By comparison, HP processing resulted in a strong enhancement of spore destruction at all temperatures. Temperature corrected Z_T values were 16.5,16.9,18.2 ℃ at 700,800,900 MPa, respectively, which were higher than the thermal z value 9.6 ℃. Hence, the spores had lower temperature sensitivity at elevated pressures. Similarly, corrected Z_P values were 714, 588, 1250 MPa at 80, 90, 100 ℃, respectively, which illustrated lower pressure sensitivity at higher temperatures. By general comparison, it was concluded that within the range operating conditions employed, the spores were relatively more sensitive to temperature than to pressure.
机译:高压灭菌设备需要有关耐压病原性和变质细菌芽孢的等压和等温破坏动力学数据。在本研究中,对牛奶中接种的产孢梭状芽胞杆菌11437孢子(10〜7 CFU / ml)进行了不同的压力,温度和时间(P,T,t)组合处理(700-900 MPa; 80-100℃; 0- 32分钟)。在处理期间,使用绝缘室将测试样品围起来,以保持等压和准等温处理条件。使用3×3全因子实验设计评估十进制还原时间(D值)以及压力和温度敏感性参数Z_T(压力常数)和Z_P(温度常数)。高压治疗通常表现出较小的压力脉冲效应(PE)(无保持时间),并且一阶模型很好地描述了压力保持时间效应(R〜2> 0.90)。较高的压力和较高的温度导致较高的破坏率和较高的微生物数量减少。在900 MPa下,温度校正后的D值在80、90、100℃下分别为9.1、3.8、0.73 min。在0.1 MPa的热处理下,分别在80、90、95、100℃下的D值分别为833、65.8、26.3、6.0分钟。相比之下,HP处理在所有温度下都大大增强了孢子破坏能力。在700,800,900 MPa下,温度校正后的Z_T值分别为16.5、16.9、18.2℃,高于热z值9.6℃。因此,孢子在升高的压力下具有较低的温度敏感性。同样,在80、90、100℃时,校正后的Z_P值分别为714、588、1250 MPa,这说明在较高温度下压力敏感性较低。通过一般比较,可以得出结论,在所采用的操作条件范围内,孢子对温度的敏感性要比对压力的敏感性高。

著录项

  • 来源
    《Journal of food engineering》 |2009年第2期|249-257|共9页
  • 作者单位

    Department of Food Science and Agriculture Chemistry, McGill University, Macdonald Campus, 21111 Lakeshore Road, Ste Anne de Bellevue, Quebec, Canada H9X 3V9;

    Department of Food Science and Agriculture Chemistry, McGill University, Macdonald Campus, 21111 Lakeshore Road, Ste Anne de Bellevue, Quebec, Canada H9X 3V9;

    Department of Food Science and Agriculture Chemistry, McGill University, Macdonald Campus, 21111 Lakeshore Road, Ste Anne de Bellevue, Quebec, Canada H9X 3V9;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    high-pressure; sterilization; spore inactivation; clostridium sporogenes; kinetics; food safety;

    机译:高压力;消毒;孢子灭活;梭状芽孢杆菌动力学;食品安全;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号