Forced-air precooling of strawberries is rarely ideal due to the non-uniform cooling rate inside precooling facilities and the simple heuristics used to select precooling duration. The aim of this work was to investigate the product temperature distribution during commercial forced-air precooling of strawberries, quantify the relationship between the ambient and product temperature and assess precooling durations. Our field studies showed that the half-cooling time (HCT) on the inside of precooling tunnels is approximately twice the HCT on the outside, facing the incoming air, but is relatively constant along the length of the tunnel and vertically within pallets. The HCT on the outside of the tunnel is strongly correlated to the HCT on the inside, enabling temperature predictions from a limited number of sensors. Temperature variations of up to 7 °C were observed at the end of precooling, suggesting that precooling should be extended in some instances to improve uniformity.
机译:由于预冷设备内部的冷却速度不均匀,并且用于选择预冷时间的简单启发法,草莓的强制空气预冷很少是理想的选择。这项工作的目的是调查草莓在商用强制空气预冷过程中的产品温度分布,量化环境温度与产品温度之间的关系,并评估预冷时间。我们的现场研究表明,预冷隧道内部的半冷却时间(HCT)大约是外部HCT的两倍,面对进入的空气,但沿隧道的长度和垂直方向在托盘内相对恒定。隧道外部的HCT与内部的HCT紧密相关,从而可以通过有限数量的传感器进行温度预测。在预冷结束时观察到高达7 C的温度变化,这表明在某些情况下应延长预冷以提高均匀性。