摘要

A ceramic substrate bonded to an electronic sensor was reported to crack during thermal testing between −46 and +71 °C. Initially, this was assumed to occur at high temperature because of the thermal expansion of a polymer pad under the sensor. However, further investigations indicated that fracture was also occurring at low temperature. This was surprising since the suspected cause of fracture was pressure exerted by the polymer pad under the ceramic. This polymer pad has a coefficient of thermal expansion much greater than any other component. Conventional wisdom suggests that this failure would happen only during expansion of the pad during high temperature phases of temperature cycling. Subsequent dynamic thermal analysis revealed that differential contraction of the steel clamp fasteners was causing pressure to be exerted on the ceramic during the initial phase of the cold cycle. In addition, lateral constraint of the polymer pad caused pressure to rise to counterintuitive levels. An alteration of the geometry of the pad proved to be the simplest and most economical solution. This was confirmed by subsequent testing.
机译:据报告,在-46至+71°C的热测试期间,粘结至电子传感器的陶瓷基板会破裂。最初,这被认为是由于传感器下方的聚合物垫的热膨胀而在高温下发生的。但是,进一步的研究表明在低温下也发生了断裂。这是令人惊讶的,因为怀疑的断裂原因是由陶瓷下面的聚合物垫施加的压力。该聚合物垫的热膨胀系数比其他任何部件都要大。传统观点认为,这种故障只会在温度循环的高温阶段膨胀垫时发生。随后的动态热分析表明,在冷循环的初始阶段,钢制紧固件的收缩收缩会导致在陶瓷上施加压力。另外,聚合物垫的横向约束导致压力上升到违反直觉的水平。事实证明,改变垫的几何形状是最简单,最经济的解决方案。随后的测试证实了这一点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号