Moisture induced epoxy swelling is a potential failure mechanism in nonhermetic packages. Epoxy materials used in the package absorb moisture and swell in a relatively humid environment. This will result in hygroscopic stresses in the material that can eventually lead to failure. The coefficient of hygroscopic swelling (CHS) is a material property that characterizes moisture induced swelling in the material. It is defined as the ratio of hygroscopic strain to the moisture concentration in the material. Prior research investigated the measurement of CHS experimentally using techniques such as thermo mechanical analysis (TMA) (Ardebili et al., 2003, "Hygroscopic Swelling and Sorption Characteristics of Epoxy Molding Compounds Used in Electronic Packaging," IEEE Trans. Compon. Packag. Technol., 26(1), pp. 206-214; Mckague et al., 1978, "Swelling and Glass Transition Relations for epoxy Matrix Material in Humid Environments," J. Appl. Polym. Sci., 22, pp. 1643-1654.), Moire interferometry (Han et al., 2003, "Measurement of the Hygroscopic Swelling Coefficient in Mold Compounds Using Moire Interferometer Experimental Techniques," IEEE Trans. Compon. Packag. Technol., 27(4), pp. 40-44), and digital image correlation (D1C) (Park and Zhang, 2007, "Investigation of Hygroscopic swelling of Polymers in Freezing Temperature," ASME International Mechanical Engineering Congress and Exposition). Some of these studies recommended investigation of improved measurement techniques, while others made some procedural assumptions that may not be applicable for all materials. One of the goals of this study was to investigate an improved technique for CHS measurement and helps to better understand the various factors that affect the measurement. The DIC technique was used to measure the moisture swelling of the epoxy material considered for use in the package. Moisture loss during the measurement results in a change in moisture concentration in the sample. While it may be thought that the moisture loss during the DIC scan can be assumed negligible due to the short test time compared with other methods, this assumption did not hold well for the current epoxy material. The ramp rate chosen for the test affects the moisture loss. It introduces a level of nonuniformity in temperature and moisture distribution in the sample. A suitable value that takes into account both of these effects was determined. The moisture loss measured during the DIC scan was accounted for in the CHS computation. In addition to this, the temperature and concentration dependence of the CHS was determined. Results indicated that the temperature and concentration effects are small for the current test material within the test temperature range. The moisture loss found during the DIC measurement leads to a nonuniform moisture distribution in the sample. This was characterized by using experimental and computational methods and the effect on the measurement was determined.
机译:湿气引起的环氧溶胀是非密封包装的潜在失效机理。包装中使用的环氧树脂材料会在相对潮湿的环境中吸收水分并膨胀。这将导致材料中出现吸湿应力,最终导致失效。吸湿膨胀系数(CHS)是表征材料中水分引起的膨胀的材料特性。它定义为吸湿应变与材料中水分含量的比率。先前的研究使用热机械分析(TMA)等技术对CHS的测量进行了实验研究(Ardebili等人,2003年,“电子包装中使用的环氧模塑化合物的吸湿性和吸着特性”,IEEE Trans。Compon。Packag。Technol ,J.Appl.Polym.Sci。,第26卷,第26卷,第1期,第206-214页; Mckague等,1978年,“潮湿环境中环氧基质材料的溶胀和玻璃化转变关系”,J.Appl.Polym.Sci。,第22页,第1643- 1654。),莫尔干涉仪(Han等人,2003,“使用莫尔干涉仪实验技术测量霉菌化合物中的吸湿膨胀系数”,IEEE Trans。Compon。Packag。Technol。,27(4),第40- 44)和数字图像相关性(D1C)(Park和Zhang,2007年,“冷冻温度下聚合物的吸湿性溶胀研究”,ASME国际机械工程大会和博览会)。这些研究中的一些建议对改进的测量技术进行研究,而另一些研究则提出了一些可能不适用于所有材料的程序假设。这项研究的目的之一是研究一种改进的CHS测量技术,并有助于更好地了解影响测量的各种因素。 DIC技术用于测量考虑用于包装的环氧材料的水分膨胀。测量期间的水分损失会导致样品中水分浓度的变化。尽管由于与其他方法相比测试时间短,可以认为DIC扫描期间的水分损失可以忽略不计,但这种假设对于当前的环氧材料并不适用。为测试选择的升温速率会影响水分流失。它引入了样品中温度和水分分布的不均匀程度。确定了考虑这两种影响的合适值。在CHS计算中考虑了DIC扫描期间测得的水分损失。除此之外,还确定了CHS的温度和浓度依赖性。结果表明,在测试温度范围内,当前测试材料的温度和浓度影响很小。 DIC测量过程中发现的水分损失会导致样品中水分分布不均匀。通过实验和计算方法对其进行表征,并确定对测量的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号