首页> 外文期刊>Journal of dairy science >Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum
【24h】

Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum

机译:白利糖度折光仪的评估以估计牛初乳中免疫球蛋白G的浓度

获取原文
获取原文并翻译 | 示例
       

摘要

Refractometry using a Brix refractometer has been proposed as a means to estimate IgG concentration in bovine maternal colostrum (MC). The refractometer has advantages over other methods of estimating IgG concentration in that the Brix refractometer is inexpensive, readily available, less fragile, and less sensitive to variation in colostral temperature, season of the year and other factors. Samples of first-milking MC were collected from 7 dairy farms in Maine, New Hampshire, Vermont, and Connecticut (n = 84) and 1 dairy farm in California (n = 99). The MC was milked from the cow at 6.1 ± 5.6 h postparturition and a sample was evaluated for Brix percentage by using an optical refractometer. Two additional samples (30 mL) were collected from the milk bucket, placed in vials, and frozen before analysis of total IgG by radial immuno-diffusion (RID) using commercially available plates and by turbidimetric immunoassay (TIA). The second sample was analyzed for total bacterial counts and co-liform counts at laboratories in New York (Northeast samples) and California (California samples). The Brix percentage (mean ± SD) was 23.8 ± 3.5, IgG concentration measured by RID was 73.4 ± 26.2 g/L, and IgG concentration measured by TIA was 67.5 ± 25.0 g/L. The Brix percentage was highly correlated (r = 0.75) with IgG analyzed by RID. The Brix percentage cut point to define high- or low-quality colostrum (50 g of IgG/L measured by RID) that classified more samples correctly given the proportion of high- (86%) and low-quality (14%) samples in this study was 21%, which is slightly lower than other recent estimates of Brix measurements. At this cut point, the test sensitivity, specificity, positive and negative predictive values, and accuracy were 92.9, 65.5, 93.5, 63.3, and 88.5%, respectively. Measurement of IgG by TIA correlated with Brix (r = 0.63) and RID (r = 0.87); however, TIA and RID methods of IgG measurement were not consistent throughout the range of samples tested. We conclude that Brix measurement of total solids in fresh MC is an inexpensive, rapid, and satisfactorily accurate method of estimating IgG concentration. A cut point of 21% Brix to estimate samples of MC >50 g/L was most appropriate for our data. Measurement of IgG in MC by TIA differed from measurement by RID.
机译:已经提出使用Brix折光仪的折光法作为估计牛母初乳(MC)中IgG浓度的方法。该折光仪相对于其他估计IgG浓度的方法具有优势,因为Brix折光仪价格便宜,易于获得,不易碎,并且对结肠温度,一年中的季节和其他因素不敏感。初乳MC样本来自缅因州,新罕布什尔州,佛蒙特州和康涅​​狄格州的7个奶牛场(n = 84)和加利福尼亚的1个奶牛场(n = 99)。产后6.1±5.6 h,从母牛身上挤出MC,并使用光学折光仪评估样品的糖度。从牛奶桶中收集另外两个样品(30 mL),放入小瓶中,冷冻,然后使用市售平板通过放射免疫扩散(RID)和浊度免疫分析(TIA)分析总IgG。在纽约(东北样本)和加利福尼亚(加利福尼亚样本)的实验室中分析了第二个样本的总细菌数和共亚型数。白利糖度百分比(平均值±SD)为23.8±3.5,通过RID测量的IgG浓度为73.4±26.2g / L,并且通过TIA测量的IgG浓度为67.5±25.0g / L。白利糖度百分比与RID分析的IgG高度相关(r = 0.75)。白利糖度切点定义了高品质或低品质的初乳(通过RID测定的50 g IgG / L),根据高品质(86%)和低品质(14%)样品的比例正确地分类了更多样品这项研究为21%,略低于最近对白利糖度测量的其他估计。在此切点,测试灵敏度,特异性,阳性和阴性预测值以及准确性分别为92.9、65.5、93.5、63.3和88.5%。通过TIA测量的IgG与白利糖度(r = 0.63)和RID(r = 0.87)相关;但是,TIA和RID IgG测量方法在整个测试样品范围内均不一致。我们得出结论,新鲜MC中总固体的白利糖度测量是一种估计IgG浓度的廉价,快速且令人满意的准确方法。估计MC> 50 g / L的样品的白利糖度的下切点最适合我们的数据。通过TIA进行的MC中IgG的测量与通过RID进行的测量不同。

著录项

  • 来源
    《Journal of dairy science》 |2013年第2期|1148-1155f5|共9页
  • 作者单位

    APC Inc., Ankeny, IA 50021;

    APC Inc., Ankeny, IA 50021;

    Department of Biological Sciences, University of New Hampshire, Durham 03824;

    Department of Biological Sciences, University of New Hampshire, Durham 03824;

    APC Europe S.A., Agda. Sant Julia 246-258. Pol. Ind. El Congost, E-08400 Granollers, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    colostrum; immunoglobulin; refractometer; validation;

    机译:初乳;免疫球蛋白折光仪验证;
  • 入库时间 2022-08-17 23:24:11