首页> 外文期刊>Journal of Constructional Steel Research >Shaking table test of buckling-restrained steel plate shear walls
【24h】

Shaking table test of buckling-restrained steel plate shear walls

机译:屈曲约束钢板剪力墙的振动台试验

获取原文
获取原文并翻译 | 示例
           

摘要

A shaking table test of a 1:3 scale semi-rigid steel frame with budding-restrained steel plate shear wall was conducted herein to study the seismic performance of this type of structure. The model was designed as ordinary steel plate shear walls, but with buckling-restrained. Its members consisted of non-simplified sections. The descriptions of the test specimen, instruments, set-up procedures were also presented. The dynamic characteristics, acceleration, displacement, and shear force were analysed. The maximum inter-storey drift angle in elastic plastic was 1/68. The lateral stiffness drop was only 12% when completely loaded. The test model did not collapse under rare earthquakes. The results showed that the seismic behaviour was adequate for survival in large seismic excitations, and the design methods of the members and the semi-rigid connections were reasonable.
机译:本文对带有萌芽约束钢板剪力墙的1:3比例半刚性钢框架进行了振动台试验,以研究此类结构的抗震性能。该模型设计为普通钢板剪力墙,但具有屈曲约束。其成员由非简化部分组成。还介绍了试样,仪器和设置程序的说明。分析了其动力特性,加速度,位移和剪切力。弹性塑料的最大层间漂移角为1/68。完全加载时,横向刚度下降仅为12%。该测试模型在罕见地震下没有崩溃。结果表明,在大地震激励下,地震行为足以生存,构件和半刚性连接的设计方法是合理的。