This work analyzes the difference in stiffness in a steel laboratory structure using clamped joints or bolted joints and analyzes if the stiffness varies in the same way when the frame is subjected to external dynamic loads that bring the joint materials to their yield strength. To make this comparison, the differences between clamp joint and bolted joint were evaluated using a novel methodology based on the analysis of the structure’s natural frequencies from accelerometers. To perform this comparison, several laboratory tests were carried out on a frame made by clamped joints and the same frame made by bolted joints, using a set of tests on a medium-scale shake table for this purpose. The results achieved have verified the methodology used as adequate.
机译:这项工作通过夹紧接头或螺栓接头分析了钢实验室结构中的刚度差异,并在框架经受外部动态载荷时以相同的方式进行分析,使接头材料带到其屈服强度。为了使这种比较,根据基于来自加速度计的结构的自然频率的分析,使用新的方法评估夹紧接头和螺栓接头之间的差异。为了执行这种比较,在夹紧接头和用螺栓接头制造的相同框架上进行了多个实验室测试,在此目的的中尺寸摇动台上使用一组测试。实现的结果已经验证了适当的方法。