In this study, the use of an internal vertical stiffener in built-up box-columns parallel to the beam web, which turns the column section into a boxed I-section in the connection region to eliminate the common continuity plates, is assessed through an experimental and numerical study. For this purpose, two full-scale exterior !beam to box-column moment connections (one with common continuity plates and the other one with a vertical stiffener as an alternative detail) are tested under reversed cyclic loading. The test results in terms of hysteresis moment-rotation curves, strain in critical stations, and observations during the tests indicate that the connection with the vertical stiffener could survive story drifts of up to 4% without any strength loss and brittle failure such as weld fracture. For further investigation of the seismic performance of the proposed detail, Finite Element Modeling (FEM) of the test specimens is also conducted in the FE software ABAQUS and validated using the test results. The results of the numerical study also confirm the satisfactory behavior of the connections with the proposed detail. (C) 2020 Elsevier Ltd. All rights reserved.
机译:在本研究中,通过与光束网的内置箱列中的内部垂直加强件在连接区域中的盒装I-段中使用,以消除公共连续板的盒装I-段。实验性和数值研究。为此目的,在反转的循环载荷下测试了两个全尺寸外部的框柱 - 柱子时刻连接(具有共同连续板的一个具有垂直加强件的另一个)。测试结果在滞后力矩旋转曲线,关键站中的应变,以及测试期间的观察结果表明,与垂直加强件的观察结果可以存活最多4%的故事,而没有任何强度损失和脆性失效,如焊接骨折。为了进一步调查所提出的细节的地震性能,测试样品的有限元建模(FEM)也在FE软件ABAQUS中进行并使用测试结果进行验证。数值研究的结果还与所提出的细节确认连接的令人满意的行为。 (c)2020 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号