The external confinement of RC columns by means of externally bonded fiber-reinforced polymer (FRP) laminates is a well established technique for strengthening and retrofitting purposes. This paper presents a pilot research that includes laboratory testing of full-scale square and rectangular RC columns externally confined with glass and basalt-glass FRP laminates and subjected to pure axial load. Specimens that are representative of full-scale building columns were designed according to a dated American Concrete Institute (ACI) 318 code (i.e., prior to 1970) for gravity loads only. The study was conducted to investigate how the external confinement affects peak axial strength and deformation of a prismatic RC column. The results showed that the FRP confinement increases concrete axial strength, but it is more effective in enhancing concrete strain capacity. The discussion of the results includes a comparison with the values obtained using existing constitutive models.
机译:借助外部粘结的纤维增强聚合物(FRP)层压板对RC柱进行外部约束是一种成熟的技术,可用于加固和翻新。本文提出了一项初步研究,其中包括对外部用玻璃和玄武岩玻璃纤维增​​强塑料层压板限制并承受纯轴向载荷的全尺寸方形和矩形RC柱进行实验室测试。代表全尺寸建筑立柱的标本是根据仅注明日期的美国混凝土协会(ACI)318规范(即1970年之前)设计的。进行该研究以研究外部约束如何影响棱柱RC柱的峰值轴向强度和变形。结果表明,FRP约束增加了混凝土的轴向强度,但在增强混凝土的应变能力方面更为有效。对结果的讨论包括与使用现有本构模型获得的值进行比较。

著录项

  • 来源
    《Journal of Composites for Construction》 |2011年第1期|p.112-123|共12页
  • 作者单位

    Dept. of Civil, Architectural, and Environmental Engineering, Univ. of Miami, 105 McArthur Engineering Bldg., Coral Gables, FL 33146-0630;

    Dept. of Structural Engineering, Univ. of Naples, Federico II, Via Claudio 21, Naples, P.O. Box 1-80125, Italy;

    Dept. of Civil and Environmental Engineering,Univ. of South Carolina, 300 Main St., Room C210, Columbia, SC 29208;

    Dept. of Civil, Architectural, and Environmental Engineering, Univ. of Miami, 323 McArthur Engineering Bldg., Coral Gables, FL 33146-0630 Dept. of Structural Engineering, Univ. of Naples, Federico II, Via Claudio 21, Naples, P.O. Box 1-80125, Italy;

    Dept. of Structural Engineering, Univ. of Naples, Federico II, Via Claudio 21, Naples, P.O. Box 1-80125, Italy;

    Dept. of Structural Engineering, Univ. of Naples,Federico II, Via Claudio 21, Naples, P.O. Box 1-80125, Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    confinement; deformability; frp laminates; full-scale RC columns; strengthening; volumetric strain;

    机译:禁闭变形能力frp层压板;全尺寸RC柱;强化;体积应变;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号