...
首页> 外文期刊>Journal of Cleaner Production >Analysis of water consumption in toilets employing Shewhart, EWMA, and Shewhart-EWMA combined control charts
【24h】

Analysis of water consumption in toilets employing Shewhart, EWMA, and Shewhart-EWMA combined control charts

机译:使用Shewhart,EWMA和Shewhart-EWMA组合控制图分析厕所的耗水量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The objective of this article is to statistically analyze and apply process control on water consumption in toilet flush devices in a public university building using Shewhart, EWMA and combined Shewhart-EWMA control charts. Data such as water volume, number of activations and flush-time duration were collected utilizing Smart-Meter sensors. A script was developed in R language to perform the appropriate statistical analysis, such as finding control charts control limits and transforming the obtained raw data into key variables: total volume per day, average flush volume, flush duration, and number of flushes per day. During the data gathering period, the regular single-flush equipment was replaced by a dual-flush model. The control charts Phase 1 is based on the collected data before the installation of the dual-flush devices, while Phase 2 is based on after replacement. After installing the new dual-flush devices, all control charts displayed visible changes based on the key variables. The replacement of the flush valves brought about a considerable reduction in water consumption in both male and female restrooms. There was a 21.72% reduction in average water consumption and a 12.09% average reduction in flushing time duration. The equipment replacement resulted in an evaluated Internal Rate of Return of 0.73%. Periodic monitoring of Shewhart Control Charts proved useful for observing large shifts of data, while EWMA control charts were more useful in locating small but constant data shifts. All chart models proved useful in identifying water consumption reduction and events such as leakages and water supply cutoffs occurring during the data gathering period. (C) 2019 Elsevier Ltd. All rights reserved.
机译:本文的目的是使用Shewhart,EWMA和组合的Shewhart-EWMA控制图,对一所公立大学大楼的厕所冲水装置中的用水量进行统计分析并应用过程控制。使用Smart-Meter传感器收集水量,激活次数和冲洗时间等数据。用R语言开发了一个脚本,以执行适当的统计分析,例如查找控制图控制极限并将获得的原始数据转换为关键变量:每日总体积,平均冲洗量,冲洗持续时间和每天冲洗次数。在数据收集期间,常规的单冲洗设备被双冲洗模型代替。控制图第1阶段基于双冲洗设备安装之前的收集数据,而第2阶段则基于更换后的数据。安装新的双冲洗设备后,所有控制图均会显示基于关键变量的可见变化。冲洗阀的更换大大减少了男女洗手间的用水量。平均耗水量减少了21.72%,冲洗时间平均减少了12.09%。更换设备后,内部收益率评估为0.73%。实践证明,对Shewhart控制图进行定期监视对于观察数据的大变化非常有用,而EWMA控制图在定位较小但恒定的数据变化时更有用。事实证明,所有图表模型都有助于识别耗水量的减少以及在数据收集期间发生的泄漏和供水中断等事件。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号