摘要

The objective of this article is to statistically analyze and apply process control on water consumption in toilet flush devices in a public university building using Shewhart, EWMA and combined Shewhart-EWMA control charts. Data such as water volume, number of activations and flush-time duration were collected utilizing Smart-Meter sensors. A script was developed in R language to perform the appropriate statistical analysis, such as finding control charts control limits and transforming the obtained raw data into key variables: total volume per day, average flush volume, flush duration, and number of flushes per day. During the data gathering period, the regular single-flush equipment was replaced by a dual-flush model. The control charts Phase 1 is based on the collected data before the installation of the dual-flush devices, while Phase 2 is based on after replacement. After installing the new dual-flush devices, all control charts displayed visible changes based on the key variables. The replacement of the flush valves brought about a considerable reduction in water consumption in both male and female restrooms. There was a 21.72% reduction in average water consumption and a 12.09% average reduction in flushing time duration. The equipment replacement resulted in an evaluated Internal Rate of Return of 0.73%. Periodic monitoring of Shewhart Control Charts proved useful for observing large shifts of data, while EWMA control charts were more useful in locating small but constant data shifts. All chart models proved useful in identifying water consumption reduction and events such as leakages and water supply cutoffs occurring during the data gathering period. (C) 2019 Elsevier Ltd. All rights reserved.
机译:本文的目的是使用Shewhart,EWMA和组合的Shewhart-EWMA控制图进行统计分析和应用卫生间冲洗设备中的水消耗。利用智能仪表传感器收集诸如水体积,激活次数和冲洗时间持续时间的数据。脚本以R语言开发,以执行适当的统计分析,例如查找控制图表控制限制并将所获得的原始数据转化为键变量:每天总量,平均冲洗体积,冲洗持续时间和每天冲洗数量。在数据收集期间,常规单冲洗设备被双冲洗模型所取代。控制图表阶段1基于在安装双冲洗设备之前收集的数据,而阶段2基于更换之后。安装新的双刷设备后,所有控制图都基于关键变量显示可见的更改。更换冲洗阀在雄性和女性卫生间的耗水量显着降低。平均耗水量减少了21.72%,水平持续时间的平均值降低12.09%。设备更换导致评估的内部返回率为0.73%。定期监测削减控制图表对于观察数据的大转移有用,而EWMA控制图在定位小但恒定的数据班次方面更有用。所有图表模型都证明可用于识别在数据收集期间发生的泄漏和供水截止等漏水减少和事件。 (c)2019 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号