首页> 外文期刊>Journal of circuits, systems and computers >An Ultra Low Voltage Low Power Self Biased Latched Comparator with Wide Input Common Mode Range for Biomedical Application
【24h】

An Ultra Low Voltage Low Power Self Biased Latched Comparator with Wide Input Common Mode Range for Biomedical Application

机译:具有宽输入共模范围的生物医学应用超低压低功耗自偏置锁存比较器

获取原文
获取原文并翻译 | 示例

摘要

This work describes an ultra low voltage, low power and self biased comparator with wide input common-mode range. The proposed comparator consists of a preamplifier followed by a regenerative back-to-back inverter latch, where two push pull NMOS and PMOS pairs are exploited to bias the preamplifier and adjust its output common mode voltage. This leads to a wide input common mode voltage range (from 0V to 390 mV). Furthermore, the operation of proposed structure is relatively insensitive to process and temperature variations due to the push pull transistors, and low power consumption is achieved through sub-threshold region operation. The comparator circuit is designed using 65-nm CMOS technology with minimum supply voltage of 0.4 V. Simulation results show an average power consumption ranging from 141nW to 188nW for different input common mode voltage levels, where a simple power gating technique is employed to further reduce the power consumption. The Monte Carlo simulation shows an average offset of 450 mu V with standard deviation of 3.3 mV. In addition, the comparator shows a kickback noise range of 0.3-2.4mV (with input common mode range from 0V to 390 mV) and input referred noise of 0.9 mV. The proposed comparator operates up to clock frequency of 1MHz in most process corners and temperature range of 0-100 degrees C which is suitable for most of the biomedical sensing applications.
机译:这项工作描述了具有宽输入共模范围的超低电压,低功耗和自偏置比较器。拟议的比较器包括一个前置放大器,后跟一个可再生的背靠背反相器锁存器,其中利用两个推挽NMOS和PMOS对偏置该前置放大器并调整其输出共模电压。这导致较宽的输入共模电压范围(从0V至390 mV)。此外,由于推挽晶体管,所提出的结构的操作对工艺和温度变化相对不敏感,并且通过亚阈值区域操作实现了低功耗。比较器电路采用65nm CMOS技术设计,最小电源电压为0.4V。仿真结果显示,对于不同的输入共模电压电平,平均功耗范围为141nW至188nW,其中采用了一种简单的电源门控技术来进一步降低功耗。功耗。蒙特卡洛模拟显示平均偏移为450μV,标准偏差为3.3 mV。此外,比较器的反冲噪声范围为0.3-2.4mV(输入共模范围为0V至390mV),输入参考噪声为0.9mV。拟议的比较器在大多数过程角点和1至100摄氏度的温度范围内均可运行高达1MHz的时钟频率,适用于大多数生物医学传感应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号