...
首页> 外文期刊>Journal of Analytical Atomic Spectrometry >Atomic spectrometry update - a review of advances in environmental analysis
【24h】

Atomic spectrometry update - a review of advances in environmental analysis

机译:原子光谱更新 - 环境分析进展综述

获取原文
获取原文并翻译 | 示例
           

摘要

In the field of air analysis, highlights within this review period included: new isotopic data for reference dust materials; a new device for preparing and mounting delicate air filter samples for X-ray analysis and use of oxygen-mediated mass-shift ion chemistry for measuring sulfur in aerosol samples by ICP-MS. The use of DGT and ionic liquids for preconcentrating trace elements and other analytes from waters has become more established. The resurgence of interest in As speciation has been noted with extensive reviews as well as methods for the challenging determination of thioarsenic species. Improvements in methodologies have achieved LODs with GC-MS that were once only possible with ICP-MS, thereby making it possible for a larger number of laboratories to undertake speciation analysis. Field preconcentration methods and hand-held XRF instruments have made it easier to screen contaminated waters, thereby allowing sampling sites to be selected more effectively. There has been renewed interest in atomic emission sources such as the arc, GD and plasmatron for the analysis of plants and soils. The upward trend in publication of LIBS methods continued but many lacked validation through comparison with established methods or analysis of CRMs. There is a clear need for closer collaboration between the physicists driving fundamental developments in plasma spectroscopy and analytical geochemists, who understand the complexities of environmental samples and the requirement to implement robust QC procedures. Interest in multivariate analysis of pXRFS spectra to predict soil properties related to fertility has increased. Much research effort continues to be devoted to characterisation of matrix-matched geological RMs, both synthetic and natural samples, particularly for in situ analysis by microanalytical techniques, such as LA-MC-ICP-MS and SIMS. Such RMs are essential to compensate for matrix effects and need to be available in sufficient quantities to enable interlaboratory comparisons based on the same RM. The increased access to MC-ICP-MS instrumentation, especially in China, is reflected in the diverse range of isotopic systems now being studied. Most studies present incremental improvements to existing separation procedures or measurement protocols.
机译:在空中分析领域,在此审查期内亮点包括:用于参考粉尘材料的新同位素数据;一种用于制备和安装精细空气过滤器样品的新装置,用于X射线分析和使用ICP-MS测量气溶胶样品中的硫的硫介导的压力离子化学。使用DGT和离子液体用于预浓缩的微量元素和来自水的其他分析物已经变得更加建立。在广泛的审查以及挑战性测定硫化物物种的情况下,已经注意到其兴趣重新提高。方法的改进已经实现了与ICP-MS仅可能仅可能的GC-MS的LOD,从而使得可以进行更大数量的实验室进行物种分析。现场预浓缩方法和手持式XRF仪器使其更容易筛选污染的水域,从而允许更有效地选择采样网站。对原子发射源的兴趣感兴趣,例如弧,GD和素质素,用于分析植物和土壤。 LIBS方法出版的上升趋势持续但通过与建立方法或CRMS分析进行比较缺乏验证。在促进血浆光谱和分析地球化学家的物理学家之间的物理学家之间有明确需要更紧密的合作,他们了解环境样本的复杂性以及实施强大的QC程序的要求。 PXRFS光谱对多变量分析的兴趣预测与生育率有关的土壤性质增加。较多的研究努力旨在致力于基质匹配的地质rms,合成和天然样品的表征,特别是通过微基体技术,例如La-MC-ICP-MS和SIMS的原位分析。这种RMS对于补偿矩阵效应是必不可少的,并且需要足够的数量可用以使基于相同的RM进行间接性比较。增加了对MC-ICP-MS仪器,特别是在中国的进入,反映在现在正在研究的各种同位素系统中。大多数研究对现有的分离程序或测量协议提高了增量改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号