首页> 外文期刊>International Orthopaedics >Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy
【24h】

Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy

机译:髋关节表面置换术的无图像导航提高了植入物的准确性

获取原文
获取原文并翻译 | 示例
       

摘要

Surface arthroplasty of the hip is increasingly popular. Optimising the position of the femoral component is essential to avoid early implant failures such as femoral neck fractures. Sixty hip surface replacements were retrospectively analysed. In 30 patients imageless navigation was used, and 30 patients were operated upon using conventional jigs. Accuracy, implant position, operating time, and complications have been recorded. The navigation device improved the implant position with high accuracy. Implant-shaft angles <130° and uncovered cancellous bone of the superior femoral neck could be safely avoided. After a significant learning curve, navigation took 15 minutes longer than conventional implantation. No complications were found in either group. Computer-assisted navigation allowed accurate implantation of the femoral component avoiding pitfalls of hip surface replacement. From our point of view the optimal placement of the femoral component outweighs the disadvantage of a longer operating time.
机译:髋关节的表面置换术越来越受欢迎。优化股骨组件的位置对于避免早期植入失败(如股骨颈骨折)至关重要。回顾性分析了60例髋关节表面置换。在30例患者中,使用了无图像导航,并且使用常规夹具对30例患者进行了手术。已经记录了准确性,植入物位置,手术时间和并发症。导航装置以高精度改善了植入物的位置。可以安全地避免植入轴角度<130°和股骨上颈的未覆盖松质骨。经过明显的学习后,导航比常规植入花费了15分钟以上。两组均未发现并发症。计算机辅助导航可以准确植入股骨组件,避免了髋关节表面置换的陷阱。从我们的角度来看,股骨组件的最佳放置要克服手术时间较长的缺点。