首页> 外文期刊>International Journal of Hydrogen Energy >Safety assessment of hydrogen disposal on vents and flare stacks at high flow rates
【24h】

Safety assessment of hydrogen disposal on vents and flare stacks at high flow rates

机译:高流量下放空口和火炬烟囱中氢气的安全评估

获取原文
获取原文并翻译 | 示例
           

摘要

We compare the point source and solid flame models for assessing the thermal flux levels from hydrogen vent flares. Substantial disagreement exists between the solid flame approach and the point source model close to the base of the flare stack. In this region, the solid flame model is more reliable and may result in higher estimates of the maximum thermal flux from the flare stack. We use the solid flame model to determine restrictions on vent heights and the location of buildings.
机译:我们比较了点源模型和固体火焰模型,以评估氢气排放火炬的热通量水平。固体火焰方法与火炬烟囱底部附近的点源模型之间存在很大分歧。在该区域中,固体火焰模型更可靠,并且可能导致对来自火炬烟囱的最大热通量的更高估计。我们使用固体火焰模型来确定对通风口高度和建筑物位置的限制。