首页> 外文期刊>International communications in heat and mass transfer >Experimental heat transfer and pressure drop study on typical, perforated, V-cut and U-cut twisted tapes in a helically corrugated heat exchanger
【24h】

Experimental heat transfer and pressure drop study on typical, perforated, V-cut and U-cut twisted tapes in a helically corrugated heat exchanger

机译:在螺旋波纹热交换器中对典型的,穿孔的,V形和U形扭曲带进行实验传热和压降研究

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, heat transfer and friction factor are experimentally studied in a double pipe heat exchanger which has an inner corrugated tube filled with various categories of twisted tapes from conventional to modified types which include perforated, V-cut and U-cut types. The twist ratios are 3,5 and 7, the hole diameter ratio are 0.11 and 0.33, the width and depth ratio of the cuts vary from 0.3 to 0.6 and the Reynolds number is changed from 5000 to 15,000 of turbulent regime. All of these factors lead to the performance of more than 350 experiments. The results of the main parameters on heat transfer and pressure drop show that the Nusselt number and friction factor for all cases of twisted tape corrugated tube are more than the empty corrugated tube. Also the Nusselt number and friction factor for corrugated tube equipped with modified twisted tapes are higher than typical tapes except those of perforated types which lead to lower Nusselt number and friction factor.
机译:在本文中,在双管式换热器中进行了传热和摩擦系数的实验研究,该换热器的内波纹管中填充了从传统类型到改进类型(包括穿孔,V形和U形)的各种扭曲带。扭曲比为3,5和7,孔径比为0.11和0.33,切口的宽度和深度比在0.3到0.6之间变化,雷诺数在5000到15,000之间变化。所有这些因素导致超过350个实验的执行。传热和压降的主要参数结果表明,所有扭曲带状波纹管的努塞尔数和摩擦系数均大于空波纹管。此外,配备了改进型扭曲带的瓦楞纸管的努塞尔数和摩擦因数比典型的带子要高,但穿孔型的那些会导致更低的努塞尔数和摩擦因数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号