首页> 外文会议>International Conference and Exhibition on Sustainable Energy and Advanced Materials >Experimental Study of Heat Transfer Enhancement in a Concentric Double Pipe Heat Exchanger with Different Axial Pitch Ratio of Perforated Twisted Tape Inserts
【24h】

Experimental Study of Heat Transfer Enhancement in a Concentric Double Pipe Heat Exchanger with Different Axial Pitch Ratio of Perforated Twisted Tape Inserts

机译:不同轴向桨型刀片型不同轴向间距比的同心双管热交换器中传热增强的实验研究

获取原文

摘要

In this study, an experimental investigation has been carried out for heat transfer and pressure drop characteristics of a concentric double pipe heat exchanger using the perforated twisted (PT) tape inserts with various axial pitch ratios. The experiments were performed using PT tape inserts with tape-twist ratio of 3.97 and the three axial pitch ratio (S_x/W= 0.56, 0.87 and 1.19) and constant the perforation hole diameter ratio (d/W= 0.16). In the experiments, hot water and cold water flowed through the inner pipe and annulus, respectively. The experiments were performed for counter current flow mode of the fluids in a turbulent flow regime with Reynolds number ranging from 5400 to 17,500. A tube with typical twisted (TT) tape insert and a plain tube were also tested for comparison. The experimental results revealed that both heat transfer rate and friction factor of the heat exchanger equipped with PT tape inserts were significantly higher than those of the plain tube and with TT tape insert. The results showed that the Nusselt number increased with decreasing S_x/W. PT tape inserts with S_x/W= 0.56, 0.87 and 1.19, provided Nusselt number up to 32%, 23% and 14% higher than TT tape insert, respectively. An average friction factor in the inner pipe generated by PT tape inserts with axial pitch ratios (S_x/W) of 0.56, 0.87 and 1.19 is found to be around 47%, 38% and 29% higher than that induced by TT tape insert, respectively. The thermal performance factor of PT tape inserts varies between 0.92 - 1.39, 0.88 - 1.34, and 0.84 - 1.28 for S_x/W= 0.56, 0.87 and 1.19, respectively. In addition, the empirical correlations of Nusselt number, friction factor and thermal performance factor were developed from the experimental results.
机译:在该研究中,使用具有各种轴向桨距比的多孔扭曲(PT)胶带插入件的同心双管热交换器的传热和压降特性进行了实验研究。使用具有3.97和三个轴间距比(S_X / W = 0.56,0.87和1.19)的胶带捻度的PT带插入件进行实验,并且恒定穿孔孔直径比(D / W = 0.16)。在实验中,分别流过内管和环的热水和冷水。在湍流状态下进行湍流流体的计数器电流流动模式进行实验,其中Reynolds数范围为5400至17,500。还测试了具有典型扭曲(TT)胶带插入件和平原管的管以进行比较。实验结果表明,配备有PT带插入件的热交换器的传热率和摩擦系数明显高于普通管和TT胶带插入物。结果表明,纽带数量随着S_X / W的降低而增加。 PT胶带插入S_X / W = 0.56,0.87和1.19,分别提供高达32%,23%和14%高于TT胶带插入物的NUSERET编号。具有0.56,0.87和1.19的轴向桨距比(S_x / W)产生的PT带插入件产生的内管的平均摩擦系数约为47%,38%和29%高于TT胶带插入件,分别。 PT胶带插入件的热性能因子分别在0.92-1.39,0.88 - 1.34和0.84 - 1.28之间变化,分别为S_X / W = 0.56,0.87和1.19。此外,从实验结果中开发了豆浆数,摩擦因子和热性能因子的经验相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号