首页> 外文期刊>Instrumentation and Measurement, IEEE Transactions on >Fabrication and Measurement of the Main Electrodes of the NMIA-BIPM Calculable Cross Capacitors
【24h】

Fabrication and Measurement of the Main Electrodes of the NMIA-BIPM Calculable Cross Capacitors

机译:NMIA-BIPM可计算交叉电容器主要电极的制造和测量

获取原文
获取原文并翻译 | 示例

摘要

Two new calculable cross capacitors are being constructed by the National Measurement Institute of Australia and the Bureau International des Poids et Mesures, with the aim of limiting sources of uncertainty to 1 nF/F, where achievable. In particular, the main electrodes, which are four stainless steel bars 470 mm long and 50 mm in diameter, must be geometrically accurate to 100 nm. An automated system based on capacitance probes has been constructed for the purpose of measuring the geometry of the bars with an uncertainty of around 20 nm. Two sets of electrodes have been finished to the required accuracy, although further improvement may be possible.
机译:澳大利亚国家测量研究所和国际局等人正在建造两个新的可计算交叉电容器,目的是在可行的情况下将不确定性源限制在1 nF / F。特别是,主电极是四个470 mm长,直径50 mm的不锈钢棒,其几何精度必须达到100 nm。为了测量棒的几何形状,已经建立了基于电容探针的自动化系统,其不确定性约为20 nm。两组电极已经精加工到所需的精度,尽管可能会进一步改善。