首页> 外文期刊>Instrumentation and Measurement, IEEE Transactions on >Testing Methods for Measuring the Effects of Stray Capacitances on High-Voltage Current Transformers
【24h】

Testing Methods for Measuring the Effects of Stray Capacitances on High-Voltage Current Transformers

机译:测量杂散电容对高压电流互感器影响的测试方法

获取原文
获取原文并翻译 | 示例

摘要

This paper evaluates different measuring systems to estimate the effect of stray capacitances between primary and secondary windings on current transformers (CTs) used in high-voltage power networks. All windings are at nearly ground potential during laboratory calibration because this is the typical configuration for almost all CT’s calibration systems. However, in service, the primary winding is at high potential, so that additional currents flow through the load due to stray capacitances between primary and secondary windings, even if the CT has an electrostatic shield for reducing these capacitances. This effect changes the CT errors determined at no potential. Experimental determination of the variation of ratio and phase displacement errors between both working conditions is evaluated for a set of different CTs using different measuring systems. These systems include from the simplest low-voltage bridge capacitance measurement to the most complex one that simultaneously applies current and voltage.
机译:本文评估了不同的测量系统,以估算初级和次级绕组之间的杂散电容对高压电网中使用的电流互感器(CT)的影响。在实验室校准期间,所有绕组都几乎处于接地电位,因为这是几乎所有CT校准系统的典型配置。但是,在使用中,初级绕组处于高电位,因此,即使CT具有用于减小这些电容的静电屏蔽,由于初级绕组和次级绕组之间的杂散电容,额外的电流也会流过负载。这种影响会改变CT误差(无可能)。对于使用不同测量系统的一组不同CT,评估了两种工作条件之间比率和相位移误差变化的实验确定。这些系统包括从最简单的低压电桥电容测量到最复杂的同时施加电流和电压的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号