首页> 外文期刊>IEEE Transactions on Instrumentation and Measurement >Shielded open-circuited sample holder for dielectric measurements of solids and liquids
【24h】

Shielded open-circuited sample holder for dielectric measurements of solids and liquids

机译:屏蔽开路样品架,用于固体和液体的介电测量

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a technique for permittivity measurements that can be used for either liquids or solid coaxial samples from near dc to gigahertz frequencies. The method uses both a full-mode model of a coaxial open-circuited termination and a capacitive method for permittivity determination. The method requires the use of an impedance bridge and a network analyzer. Measurements indicate good accuracy for the permittivity over a very wide band of frequencies. For high permittivity materials the sample surfaces must be metallized. An uncertainty analysis is also presented.
机译:本文介绍了一种介电常数测量技术,该技术可用于液体或固体同轴样品,频率范围从dc到GHz。该方法使用同轴开路端接的全模式模型和电容率确定的电容方法。该方法需要使用阻抗桥和网络分析仪。测量表明在很宽的频率范围内,介电常数的准确性很高。对于高介电常数的材料,样品表面必须金属化。还提出了不确定性分析。