A Digital-Calibration Technique for Redundant Radix-4 Pipelined Analog-to-Digital Converters

机译:冗余Radix-4流水线模数转换器的数字校准技术

获取原文
获取原文并翻译 | 示例

摘要

This paper describes a digital-calibration technique, which corrects gain errors due to capacitor mismatch and offset errors due to charge injection in redundant radix-4 pipelined analog-to-digital converters (ADCs). The error coefficients are directly measured using an integral nonlinearity (INL) plot. The proposed method simplifies the error-measurement process and removes on-chip measurement circuits in the ADC. Computer simulations show that the maximum INL of 15 LSB in an uncalibrated 15-bit ADC is reduced to less than 0.3 LSB using the digital calibration.
机译:本文介绍了一种数字校准技术,该技术可校正由于电容器不匹配而引起的增益误差和由于冗余radix-4流水线模数转换器(ADC)中的电荷注入而引起的失调误差。使用积分非线性(INL)图直接测量误差系数。所提出的方法简化了误差测量过程,并消除了ADC中的片上测量电路。计算机仿真显示,使用数字校准后,未经校准的15位ADC的最大INL为15 LSB,减小到小于0.3 LSB。