A method using the power supply current for fault detection in analog and mixed-mode circuits is presented. A new unified fault detection procedure is introduced, and its fault detection capability is estimated. The procedure combines the rms value and the magnitude and phase components of the power supply current. Certain required discrimination factors are defined, and their values are adjusted to include circuit parameter deviations and matching dependencies for the efficient application of the method. Representative results from the simulation of an operational amplifier (opamp) and a flash analog-to-digital converter circuit are given, showing the effectiveness of the proposed method.
机译:提出了一种使用电源电流在模拟和混合模式电路中进行故障检测的方法。介绍了一种新的统一故障检测程序,并对其故障检测能力进行了估计。该过程结合了均方根值,电源电流的幅度和相位分量。定义了某些所需的判别因子,并对其值进行了调整,以包括电路参数偏差和匹配相关性,以实现该方法的有效应用。给出了从运算放大器(运放)和闪存模数转换器电路仿真得到的代表性结果,表明了该方法的有效性。