首页> 外文期刊>IEEE Transactions on Instrumentation and Measurement >A method for calibration of partial discharge calibrators
【24h】

A method for calibration of partial discharge calibrators

机译:局部放电校准器的校准方法

获取原文
获取原文并翻译 | 示例

摘要

A method for calibration of partial discharge calibrators has been developed based on passive integration of the induced charge. The voltage over a known capacitor is measured by a calibrated digital sampling voltmeter and the charge is calculated as the voltage multiplied by the capacitance. The best achieved uncertainty is /spl plusmn/2% with a coverage factor k=2.
机译:基于感应电荷的无源积分,已经开发出一种用于校准局部放电校准器的方法。已知电容器上的电压由校准的数字采样电压表测量,并且电荷计算为电压乘以电容。获得的最佳不确定度为/ spl plusmn / 2%,覆盖因子k = 2。