Concentrations of cat and dust-mite allergens in dust samples from 92 large US office buildings from the BASE Study

机译:BASE研究显示,来自92座美国大型办公大楼的灰尘样品中猫和尘螨过敏原的浓度

获取原文
获取原文并翻译 | 示例
       

摘要

The concentrations of cat (Fel d1) and dust-mite (Der f1 and Der p1) allergens were measured in 92 large office buildings in the US Environmental Protection Agency's Building Assessment Survey and Evaluation (BASE) Study (251 dust samples; one to four samples per building). Fel d1 was detected in almost all buildings and samples (91 buildings, 99%; 235 samples, 94%; range: < 0.01-19 μg/g; median: 0.3 μg/g). Cat allergen exceeded 1 μg/g (a lower symptom threshold) in 56 samples (22%) from 45 buildings, but exceeded 8 μg/g (a sensitixation threshold) in only two samples (1%) from two buildings. Der f1 or Der p1 was found in approximately half of all buildings and samples (63 and 70% of buildings; 45 and 51% of samples; range: < 0.01-53 蘥/g and < 0.01-25 μg/g; median: < 0.02 and 0.03 μg/g, respectively). Mite allergen exceeded -2 μg/g (a sensitization threshold) in seven samples (3%) from five buildings and exceeded 10 μg/g (a symptom threshold) in three samples (1%) from three buildings. Fel d1 concentration was significantly higher in samples collected in summer (June to September, 48 buildings), but cat allergen was not correlated with either mite allergen. Der f1, but not Der p1, concentration tended to be higher in samples collected in winter (December to April, 44 buildings), and the two mite allergens were significantly correlated only in winter. Cat and mite allergens were detected in 78% of representative US office buildings, but the concentrations seldom exceeded levels associated with sensitization or symptom provocation.
机译:在美国环境保护署的建筑评估调查和评估(BASE)研究中,对92座大型办公楼中的猫(Fel d1)和尘螨(Der f1和Der p1)过敏原进行了浓度测量(251份灰尘样本;一到四次)每个建筑物的样本)。在几乎所有建筑物和样品中检测到Fel d1(91栋建筑物,99%; 235个样品,94%;范围:<0.01-19μg/ g;中位数:0.3μg/ g)。来自45个建筑物的56个样本(22%)中的猫过敏原超过1μg/ g(症状阈值较低),但是来自两个建筑物的两个样本(1%)中猫过敏原均超过8μg/ g(敏化阈值)。在所有建筑物和样本的大约一半中发现了Der f1或Der p1(63%和70%的建筑物; 45%和51%的样本;范围:<0.01-53蘥/ g和<0.01-25μg/ g;中位数:分别<0.02和0.03μg/ g)。来自五个建筑物的七个样本(3%)中的螨过敏原超过-2μg/ g(致敏阈值),来自三个建筑物的三个样本(1%)中超过10μg/ g(症状阈值)。夏季(6月至9月,48座建筑物)采集的样品中的d1浓度明显更高,但猫过敏原与任何一种螨过敏原均无关。在冬季(12月至4月,共44栋建筑物)收集的样本中,Der f1而不是Der p1的浓度趋于较高,并且仅在冬季,这两种螨过敏原显着相关。在78%的美国代表性办公大楼中检测到猫和螨过敏原,但其浓度很少超过与致敏或症状刺激相关的水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号