【24h】

Statistical Gate Delay Model for Multiple Input Switching

机译:多输入切换的统计门延迟模型

获取原文
获取原文并翻译 | 示例

摘要

In this paper, we propose a calculation method of gate delay for SSTA (Statistical Static Timing Analysis) considering MIS (Multiple Input Switching). In SSTA, statistical maximum/minimum operation is necessary to calculate the latest/fastest arrival time of multiple input gate. Most SSTA approaches calculate the distribution in the latest/fastest arrival time under SIS (Single Input Switching assumption), resulting in ignoring the effect of MIS on the gate delay and the output transition time. MIS occurs when multiple inputs of a gate switch nearly simultaneously. Thus, ignoring MIS causes error in the statistical maximum/minimum operation in SSTA. We propose a statistical gate delay model considering MIS. We verify the proposed method by SPICE based Monte Carlo simulations. Experimental results show that the neglect of MIS effect leads to 80% error in worst case. The error of the proposed method is less than 20%.
机译:在本文中,我们提出了一种考虑MIS(多输入切换)的SSTA(统计静态时序分析)的门控延迟的计算方法。在SSTA中,需要统计最大/最小运算才能计算多输入门的最新/最快到达时间。大多数SSTA方法根据SIS(单输入切换假设)计算最新/最快到达时间的分布,从而忽略了MIS对门延迟和输出转换时间的影响。当门的多个输入几乎同时切换时,就会发生MIS。因此,忽略MIS会导致SSTA中统计最大值/最小值操作的错误。我们提出了一种考虑MIS的统计门控延迟模型。我们通过基于SPICE的蒙特卡洛模拟验证了所提出的方法。实验结果表明,在最坏的情况下,忽略MIS效应会导致80%的误差。该方法的误差小于20%。