As for distribution wire, overhead cable, and outdoor terminal joints, since their insulators and sheathes are exposed outdoors, the environmental stress affects their deterioration progress. Recently, there being few opportunity of equipment replacement, the numbers of old equipments on their field have been increasing, and so the influence of the environmental stress accumulation has been anticipated. Therefore it is hoped for the development of the environmental resistance test to be able to assess the stress received in the periods of being used. However, at present there is not enough explanation about test procedure and criteria. Environmental deterioration states of the equipments which were not necessarily understood.%配電用電線,架空ケーブル及び屋外終端接続部は,絶縁体ヤシースが屋外に暴露されるため,rn環境ストレスの影響が劣化の進行を左右する。一九 近年は,設備更新の機会が少なく,設備がrn高経年化しており,環境ストレスの蓄積による影響が懸念されている。よって,使用期間に受けrnる環境ストレスを評価できる環境試験の開発が望まれている。しかし現状は,各種規格の試験方rn法や判定基準の根拠に対する説明及び現行規格に適合した用品類に対する使用条件下での劣化状rn況の把握は十分とは言えない。
机译:对于配电线,架空电缆和室外端子接头,由于其绝缘子和护套暴露在室外,环境压力影响其老化进度,近来设备更换的机会很少,其领域中的旧设备数量已经大大增加。因此,已经预期到了环境应力累积的影响。希望耐环境测试的发展能够评估在使用期间承受的应力,但是目前还不够。设备的环境退化状态不一定理解。%配电线,架空电缆和室外终端连接会受到环境压力的影响,因为绝缘子的护套暴露在室外。它影响恶化的进程。 19近年来,设备更新的机会很少,设备已经老化,并且人们担心环境压力的累积。因此,期望开发一种能够评估使用期间经受的环境压力的环境测试。但是,目前还不能说足以解释各种标准的测试方法和判断标准的依据,并了解在符合当前标准的商品使用条件下的劣化情况。